Vertebroplasty - Experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate

被引:122
作者
Loeffel, Mario [1 ]
Ferguson, Stephen J. [1 ]
Nolte, Lutz-P. [1 ]
Kowal, Jens H. [1 ]
机构
[1] Univ Bern, Inst Surg Technol & Biomech, MEM Res Ctr, CH-3014 Bern, Switzerland
关键词
vertebroplasty; leakage; PMMA; bone cement; viscosity; porosity; injection speed;
D O I
10.1097/BRS.0b013e3181732aa9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. This is an experimental study on an artificial vertebra model and human cadaveric spine. Objective. Characterization of polymethylmethacrylate (PMMA) bone cement distribution in the vertebral body as a function of cement viscosity, bone porosity, and injection speed. Identification of relevant parameters for improved cement flow predictability and leak prevention in vertebroplasty. Summary of Background Data. Vertebroplasty is an efficient procedure to treat vertebral fractures and stabilize osteoporotic bone in the spine. Severe complications result from bone cement leakage into the spinal canal or the vascular system. Cement viscosity has been identified as an important parameter for leak prevention but the influence of bone structure and injection speed remain obscure. Methods. An artificial vertebra model based on open porous aluminum foam was used to simulate bone of known porosity. Fifty-six vertebroplasties with 4 different starting viscosity levels and 2 different injection speeds were performed on artificial vertebrae of 3 different porosities. A validation on a human cadaveric spine was executed. The experiments were radiographically monitored and the shape of the cement clouds quantitatively described with the 2 indicators circularity and mean cement spreading distance. Results. An increase in circularity and a decrease in mean cement spreading distance was observed with increasing viscosity, with the most striking change occurring between 50 and 100 Pas. Larger pores resulted in significantly reduced circularity and increased mean cement spreading distance whereas the effect of injection speed on the 2 indicators was not significant. Conclusion. Viscosity is the key factor for reducing the risk of PMMA cement leakage and it should be adapted to the degree of osteoporosis encountered in each patient. It may be advisable to opt for a higher starting viscosity but to inject the material at a faster rate.
引用
收藏
页码:1352 / 1359
页数:8
相关论文
共 31 条
[1]
Al-Assir I, 2000, AM J NEURORADIOL, V21, P159
[2]
Development and application of a micro-capillary rheometer for in-vitro evaluation of parenteral injectability [J].
Allahham, A ;
Mainwaring, D ;
Stewart, P ;
Marriott, J .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 2004, 56 (06) :709-716
[3]
Use of a screw-syringe injector for cement delivery during kyphoplasty: Technical report [J].
Amar, AP ;
Larsen, DW ;
Teitelbaum, GP .
NEUROSURGERY, 2003, 53 (02) :380-382
[4]
Anderson S R, 2001, Pain Pract, V1, P46
[5]
Anselmetti GC, 2005, RADIOL MED, V110, P262
[6]
ASKEW M J, 1984, Journal of Orthopaedic Research, V1, P412
[7]
High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: An experimental model and study on cement leakage [J].
Baroud, Gamal ;
Crookshank, Meghan ;
Bohner, Marc .
SPINE, 2006, 31 (22) :2562-2568
[8]
Percutaneous vertebroplasty for pain relief and spinal stabilization [J].
Barr, JD ;
Barr, MS ;
Lemley, TJ ;
McCann, RM .
SPINE, 2000, 25 (08) :923-928
[9]
Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure [J].
Bohner, M ;
Gasser, B ;
Baroud, G ;
Heini, P .
BIOMATERIALS, 2003, 24 (16) :2721-2730
[10]
Cementing techniques in hip resurfacing [J].
Chandler, M ;
Kowalski, RSZ ;
Watkins, ND ;
Briscoe, A ;
New, AMR .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :321-331