Contrast-enhanced ultrasound versus MS-CT in blunt abdominal trauma

被引:37
作者
Clevert, D. -A. [1 ,2 ]
Weckbach, S. [1 ]
Minaifar, N. [1 ]
Clevert, D. -A. [1 ,2 ]
Stickel, M. [3 ]
Reiser, M. [1 ]
机构
[1] Univ Munich, Dept Clin Radiol, Univ Hosp Grosshadern, D-81377 Munich, Germany
[2] Charite Univ Med Berlin, Med Clin Nephrol & Internal Intens Care, Berlin, Germany
[3] Univ Munich, Klinikum Grosshadern, Dept Surg, D-81377 Munich, Germany
关键词
trauma; contrast-enhanced ultrasound; multislice computed tomography;
D O I
10.3233/CH-2008-1080
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the effectiveness of contrast-enhanced ultrasound (CEUS) in the diagnosis and characterization of hepatic, renal and splenic traumatic injuries versus conventional ultrasound ( US) and multislice computed tomography (MS-CT). Between January 2005 and January 2007, 78 patients ( 48 males, 30 females, mean age 56 years) with blunt abdominal trauma were examined by conventional US, CEUS and MS-CT. CEUS employed a low-MI technique using 1.2 to 2.4 ml of SonoVue (Bracco, Italy) i.v. and a multifrequency transducer (2-4 MHz, Siemens, Sequoia, Acuson). CT examinations were performed on a 64 detector CT scanner ( Somatom Sensation 16 or 64, Siemens Medical Systems, Forchheim, Germany) before and after administration of 120 ml intravenous contrast agent (Solutrast(R), Bracco, Milan, Italy) followed by 50 ml saline. The presence of hepatic, renal and splenic injuries was analyzed and the conspicuousness of findings was assessed. In 15 of the 78 patients conventional US identified solid organ injuries: 8 hepatic, 2 renal and 5 splenic injuries. CEUS identified 3 more injuries ( 2 hepatic and 1 splenic) that had been missed by conventional US. CEUS identified traumatic lesions in 18/78 patients. In one of the 18 patients even active bleeding could be identified by CEUS. In CEUS solid organ injuries appeared hypoechoic. MS-CT identified 18 solid organ injuries in 78 patients, corroborating the CEUS results. CEUS greatly improves the visualization and characterization of hepatic, renal and splenic injuries compared to conventional ultrasound and correlates well with MS-CT. The imaging technique detects even minor blood flow and is able to depict vascular structures in detail. At our institution it is used as an additional examination technique which supplements MS-CT in unclear cases. Owing to its bedside availability, CEUS provides a good alternative to MS-CT, especially in patients with contraindications to CT contrast agents ( e. g. due to renal failure or severe allergy) and in hemodynamically compromised patients.
引用
收藏
页码:155 / 169
页数:15
相关论文
共 29 条
[1]   Ultrasound imaging with SonoVue: Low mechanical index real-time imaging [J].
Bauer, A ;
Solbiati, L ;
Weissman, N .
ACADEMIC RADIOLOGY, 2002, 9 :S282-S284
[2]   Science, medicine, and the future - Microbubble contrast agents: a new era in ultrasound [J].
Blomley, MJK ;
Cooke, JC ;
Unger, EC ;
Monaghan, MJ ;
Cosgrove, DO .
BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7296) :1222-1225
[3]  
Bokor D, 2000, AM J CARDIOL, V86, p19G
[4]   Blunt abdominal trauma: Screening US in 2,693 patients [J].
Brown, MA ;
Casola, G ;
Sirlin, CB ;
Patel, NY ;
Hoyt, DB .
RADIOLOGY, 2001, 218 (02) :352-358
[5]  
Catalano Orlando, 2004, Radiol Med, V108, P454
[6]   Abdominal injuries without hemoperitoneum: A potential limitation of focused abdominal sonography for trauma [FAST] [J].
Chiu, WC ;
Cushing, BM ;
Rodriguez, A ;
Ho, SM ;
Mirvis, SE ;
Shanmuganathan, K ;
Stein, M .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (04) :617-625
[7]   Technology overview: SonoVue (Bracco, Milan) [J].
Greis, C .
EUROPEAN RADIOLOGY, 2004, 14 :P11-P15
[8]   Tissue harmonic and contrast-specific imaging: back to gray scale in ultrasound [J].
Lencioni, R ;
Cioni, D ;
Bartolozzi, C .
EUROPEAN RADIOLOGY, 2002, 12 (01) :151-165
[9]  
Miele Vittorio, 2004, Radiol Med, V108, P82
[10]   Multidetector CT evaluation of abdominal trauma [J].
Miller, LA ;
Shanmuganathan, K .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2005, 43 (06) :1079-+