Frame-by-frame PRESS 1H-MRS of the brain at 3 T:: The effects of physiological motion

被引:20
作者
Katz-Brull, R [1 ]
Lenkinski, RE [1 ]
机构
[1] Harvard Univ, Ctr Adv Imaging, Sch Med,Dept Radiol, Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
关键词
3; T; proton MR spectroscopy; brain; frame-byframe;
D O I
10.1002/mrm.10670
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
H-1-MRS at high field has been increasingly utilized to study brain metabolism in healthy and pathological states. The aim of this work was to determine the effects of physiological motion on the results of this exam in the presence of the increased susceptibility differences at high field. Single voxel spectra of various regions in the human brain were acquired using frame-by-frame PRESS H-1-MRS at a 0.5 Hz sampling rate. The frame-by-frame variations of the FID phase and the frequency and fractional amplitude variations of the residual water-signal were analyzed. In the human brain the standard deviations of these variations were 3.9 +/- 0.5degrees 0.83 +/- 0.32 Hz, and 0.028 +/- 0.013 of the mean amplitude (n = 15). In a motionless phantom, smaller phase and frequency variations were detected in water-suppressed acquisitions. However, the end effects of physiological motion on PRESS H-1-MRS of the brain at 3 T were negligible. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:184 / 187
页数:4
相关论文
共 22 条
[1]   The sensitivity of low flip angle RARE imaging [J].
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :176-184
[2]   Single-voxel proton MRS of the human brain at 1.5T and 3.0T [J].
Barker, PB ;
Hearshen, DO ;
Boska, MD .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) :765-769
[3]   SPATIAL LOCALIZATION IN NMR-SPECTROSCOPY INVIVO [J].
BOTTOMLEY, PA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 508 :333-348
[4]   BRAIN MOTION - MEASUREMENT WITH PHASE-CONTRAST MR IMAGING [J].
ENZMANN, DR ;
PELC, NJ .
RADIOLOGY, 1992, 185 (03) :653-660
[5]   HUMAN-BRAIN MOTION AND CEREBROSPINAL-FLUID CIRCULATION DEMONSTRATED WITH MR VELOCITY IMAGING [J].
FEINBERG, DA ;
MARK, AS .
RADIOLOGY, 1987, 163 (03) :793-799
[6]  
Felblinger J, 1998, NMR BIOMED, V11, P107, DOI 10.1002/(SICI)1099-1492(199805)11:3<107::AID-NBM525>3.0.CO
[7]  
2-I
[8]  
Gonen O, 2001, AM J NEURORADIOL, V22, P1727
[9]   Restoration of motion-related signal loss and line-shape deterioration of proton MR spectra using the residual water as intrinsic reference [J].
Helms, G ;
Piringer, A .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :395-400
[10]  
Henry PG, 1999, MAGN RESON MED, V42, P636, DOI 10.1002/(SICI)1522-2594(199910)42:4<636::AID-MRM4>3.0.CO