Relative effectiveness of interposed abdominal compression CPR: Sensitivity analysis and recommended compression rates

被引:8
作者
Babbs, CF
机构
[1] Purdue Univ, Dept Basic Med Sci, W Lafayette, IN 47907 USA
[2] Indiana Univ, Sch Med, Indianapolis, IN 46204 USA
关键词
coronary perfusion pressure; guidelines; heart arrest; IAC-CPR;
D O I
10.1016/j.resuscitation.2005.02.015
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Interposed abdominal compression, IAC-CPR incorporates alternating chest and abdominal compressions to generate enhanced artificial circulation during cardiac arrest. The technique has been generally successful in improving blood flow and survival compared to standard CPR; however, some questions remain. Objective: To determine "why does IAC-CPR produce more apparent benefit in some subjects than in others?" and "what is the Proper compression rate, given that there are actually two compressions (chest and abdomen) in each cycle?" Method: Computer models provide a means to search for subtle effects in complex systems. The present study employs a validated 12-compartment mathematical model of the human circulation to explore the effects upon systemic perfusion pressure of changes in 35 different variables, including vascular resistances, vascular compliances, and rescuer technique. CPR with and without IAC was modeled. Results and conclusions: Computed results show that the effect of 100 mmHg abdominal compressions on systemic perfusion pressure is relatively constant (about 16 mmHg augmentation). However, the effect of chest compression depends strongly upon chest compression frequency and technique. When chest compression is less effective, as is often true in adults, the addition of IAC produces relatively dramatic augmentation (e.g. from 24 to 40 mmHg). When chest compression is more effective, the apparent augmentation with IAC is relatively less (e.g. from 60 to 76 mmHg). The optimal frequency for uninterrupted IAC-CPR is near 50 complete cycles/min with very little change in efficacy over 20-100 cycles/min. In theory, the modest increase in systemic perfusion pressure produced by IAC can make up in part for poor or ineffective chest compressions in CPR. IAC appears relatively less effective in circumstances when chest pump output is high. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:347 / 355
页数:9
相关论文
共 36 条
[1]  
ANTONI H, 1996, COMPREHENSIVE HUMAN, V2, P1801
[2]   CPR techniques that combine chest and abdominal compression and decompression - Hemodynamic insights from a spreadsheet model [J].
Babbs, CF .
CIRCULATION, 1999, 100 (21) :2146-2152
[3]   PRECLINICAL STUDIES OF ABDOMINAL COUNTERPULSATION IN CPR [J].
BABBS, CF .
ANNALS OF EMERGENCY MEDICINE, 1984, 13 (09) :761-763
[5]   Interposed abdominal compression CPR: a comprehensive evidence based review [J].
Babbs, CF .
RESUSCITATION, 2003, 59 (01) :71-82
[6]   Optimum compression to ventilation ratios in CPR under realistic, practical conditions: a physiological and mathematical analysis [J].
Babbs, CF ;
Kern, KB .
RESUSCITATION, 2002, 54 (02) :147-157
[7]   RELATIONSHIP OF BLOOD-PRESSURE AND FLOW DURING CPR TO CHEST COMPRESSION AMPLITUDE - EVIDENCE FOR AN EFFECTIVE COMPRESSION THRESHOLD [J].
BABBS, CF ;
VOORHEES, WD ;
FITZGERALD, KR ;
HOLMES, HR ;
GEDDES, LA .
ANNALS OF EMERGENCY MEDICINE, 1983, 12 (09) :527-532
[8]  
BABBS CF, 1986, CIRCULATION, V74, P37
[10]   CARDIAC, THORACIC, AND ABDOMINAL PUMP MECHANISMS IN CARDIOPULMONARY RESUSCITATION - STUDIES IN AN ELECTRICAL MODEL OF THE CIRCULATION [J].
BABBS, CF ;
WEAVER, JC ;
RALSTON, SH ;
GEDDES, LA .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1984, 2 (04) :299-308