Fuel cell energy generation and recovery cycle analysis for residential application

被引:22
作者
Baniasadi, Ehsan [1 ]
Alemrajabi, Ali Akbar [2 ]
机构
[1] So Illinois Univ, Dept Mech Engn, Carbondale, IL 62901 USA
[2] Isfahan Univ Technol, Dept Mech Engn, Esfahan 8415683111, Iran
关键词
Solid oxide fuel cell; Exergy; Cooling load; Efficiency; Residential;
D O I
10.1016/j.ijhydene.2010.03.015
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Today's concern regarding limited fossil fuel resources and their contribution to environmental pollution have changed the general trend to utilization of high efficiency power generation facilities like fuel cells. According to annual reducing capital cost of these utilities, their entrance to commercial level is completely expected. Hot exhaust gases of Solid Oxide Fuel Cells (SOFC) are potentially applicable in heat recovery systems. In the present research, a SOFC with the capacity of 215 kW has been combined with a recovery cycle for the sake of simultaneous of electric power, cooling load and domestic hot water demand of a hotel with 4600 m(2) area. This case study has been evaluated by energy and exergy analysis regarding exergy loss and second law efficiency in each component. The effect of fuel and air flow rate and also current density as controlling parameters of fuel cell performance have been studied and visual software for energy-exergy analysis and parametric study has been developed. At the end, an economic study of simultaneous energy generation and recovery cycle in comparison with common residential power and energy systems has been done. General results show that based on fuel lower heating value, the maximum efficiency of 83 percent for simultaneous energy generation and heat recovery cycle can be achieved. This efficiency is related to typical climate condition of July in the afternoon, while all the electrical energy, cooling load and 40 percent of hot water demand could be provided by this cycle. About 49 percent of input exergy can be efficiently recovered for energy requirements of building. Generator in absorption chiller and SOFC are the most destructive components of exergy in this system. (C) 2010 Professor T. Nejat Veziroglu. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:9460 / 9467
页数:8
相关论文
共 9 条
[1]   The financial viability of an SOFC cogeneration system in single-family dwellings [J].
Alanne, Kari ;
Saari, Arto ;
Ugursal, V. Ismet ;
Good, Joel .
JOURNAL OF POWER SOURCES, 2006, 158 (01) :403-416
[2]  
[Anonymous], 1971, NASA
[3]   Evaluation of system configurations for solid oxide fuel cell-based micro-combined heat and power generators in residential applications [J].
Braun, R. J. ;
Klein, S. A. ;
Reindl, D. T. .
JOURNAL OF POWER SOURCES, 2006, 158 (02) :1290-1305
[4]  
Campanari, 2000, J POWER SOURCES, V92
[5]  
FARHAD S, 2010, INT J HYDROGEN E JAN
[6]   Fuel cell modelling for building cogeneration applications [J].
Ferguson, A ;
Ugursal, VI .
JOURNAL OF POWER SOURCES, 2004, 137 (01) :30-42
[7]   Solid oxide fuel cell systems for distributed power generation and cogeneration (Reprinted from Int J Hydrogen Energy, vol 33, pg 2087-96, 2008) [J].
Verda, Vittorio ;
Quaglia, Michele Cali .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (16) :7097-7106
[8]  
Wark K., 1988, Thermodynamics, Vfifth
[9]  
WINIARSKI DW, 2004, ANAL IECC2003 CHILLE