Sustained prediction ability of net analyte preprocessing methods using reduced calibration sets. Theoretical and experimental study involving the spectrophotometric analysis of multicomponent mixtures

被引:40
作者
Goicoechea, HC
Olivieri, AC
机构
[1] Univ Nacl Rosario, Dept Quim Analit, Fac Ciencias Bioquim & Farmaceut, RA-2000 Rosario, Argentina
[2] Univ Nacl Litoral, Lab Contol Calidad, Catedra Quim Analit 1, Fac Bioquim & Ciencias Biol, RA-3000 Santa Fe, Argentina
关键词
D O I
10.1039/b100422k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A newly developed multivariate method involving net analyte preprocessing (NAP) was tested using central composite calibration designs of progressively decreasing size regarding the multivariate simultaneous spectrophotometric determination of three active components (phenylephrine, diphenhydramine and naphazoline) and one excipient (methylparaben) in nasal solutions. Its performance was evaluated and compared with that of partial least-squares (PLS-1). Minimisation of the calibration predicted error sum of squares (PRESS) as a function of a moving spectral window helped to select appropriate working spectral ranges for both methods. The comparison of NAP and PLS results was carried out using two tests: (1) the elliptical joint confidence region for the slope and intercept of a predicted versus actual concentrations plot for a large validation set of samples and (2) the D-optimality criterion concerning the information content of the calibration data matrix. Extensive simulations and experimental validation showed that, unlike PLS, the NAP method is able to furnish highly satisfactory results when the calibration set is reduced from a full four-component central composite to a fractional central composite, as expected from the modelling requirements of net analyte based methods.
引用
收藏
页码:1105 / 1112
页数:8
相关论文
共 55 条
[1]   NEAR-INFRARED REFLECTANCE SPECTROSCOPY - DIFFERENT STRATEGIES FOR LOCAL CALIBRATIONS IN ANALYSES OF FORAGE QUALITY [J].
AASTVEIT, AH ;
MARUM, P .
APPLIED SPECTROSCOPY, 1993, 47 (04) :463-469
[2]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]   Experimental design .1. Screening [J].
Araujo, PW ;
Brereton, RG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (01) :26-31
[4]   Genetic-algorithm-based wavelength selection in multicomponent spectrometric determinations by PLS: Application on indomethacin and acemethacin mixture [J].
Arcos, MJ ;
Ortiz, MC ;
Villahoz, B ;
Sarabia, LA .
ANALYTICA CHIMICA ACTA, 1997, 339 (1-2) :63-77
[5]  
Atkinson A.C., 1992, OPTIMUM EXPT DESIGNS
[6]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[7]   An enhanced algorithm for linear multivariate calibration [J].
Berger, AJ ;
Koo, TW ;
Itzkan, I ;
Feld, MS .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :623-627
[8]   Quantitation of the active compound and major excipients in a pharmaceutical formulation by near infrared diffuse reflectance spectroscopy with fibre optical probe [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
delaPezuela, C .
ANALYTICA CHIMICA ACTA, 1996, 333 (1-2) :147-156
[9]   UV-spectrophotometric determination of ketoprofen and paraben in a gel preparation by partial least-squares calibration [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
AlaouiIsmaili, S .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (07) :967-972
[10]   Resolution by polarographic techniques of atrazine-simazine and terbutryn-prometryn binary mixtures by using PLS calibration and artificial neural networks [J].
Cabanillas, AG ;
Díaz, TG ;
Díez, NMM ;
Salinas, F ;
Burguillos, JMO ;
Viré, JC .
ANALYST, 2000, 125 (05) :909-914