New trend in sample preparation: on-line microextraction in packed syringe for liquid and gas chromatography applications - I. Determination of local anaesthetics in human plasma samples using gas chromatography-mass spectrometry

被引:320
作者
Abdel-Rehim, M [1 ]
机构
[1] AstraZeneca R&D Sodertalje, DMPK & BAC, SE-15185 Sodertalje, Sweden
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 801卷 / 02期
关键词
microextraction in packed syringe; anaesthetics;
D O I
10.1016/j.jchromb.2003.11.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new technique for sample preparation on-line with LC and GC-MS assays was developed. Microextraction in a packed syringe (MEPS) is a new miniaturised, solid-phase extraction technique that can be connected on-line to GC or LC without any modifications. In MEPS approximately I mg of the solid packing material is inserted into a syringe (100-250 mul) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising. It is very easy to use, fully automated, of low cost and rapid in comparison with previously used methods. This paper presents the development and validation of a method for microextraction in packed syringe MEPS on-line with GC-MS. Local anaesthetics in plasma samples were used as model substances. The method was validated and the standard curves were evaluated by the means of quadratic regression and weighted by inverse of the concentration: 1/x for the calibration range 5-2000 nM. The applied polymer could be used more than 100 times before the syringe was discarded. The extraction recovery was between 60 and 90%. The results showed close correlation coefficients (R > 0.99) for all analytes in the calibration range studied. The accuracy of MEPS-GC-MS was between 99 and 115% and the inter-day precision (n = 3 days), expressed as the relative standard deviation (R.S.D.%), was 3-10%. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:317 / 321
页数:5
相关论文
共 17 条
[1]   On-line derivatization utilizing solid-phase microextraction (SPME) for determination of busulphan in plasma using gas chromatography-mass spectrometry (GC-MS) [J].
Abdel-Rehim, M ;
Hassan, Z ;
Blomberg, L ;
Hassan, M .
THERAPEUTIC DRUG MONITORING, 2003, 25 (03) :400-406
[2]   Determination of ropivacaine and its metabolites in human plasma using solid phase microextraction and GG-NPD/GC-MS [J].
Abdel-Rehim, M ;
Andersson, M ;
Portelius, E ;
Norsten-Höög, C ;
Blomberg, LG .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (08) :313-321
[3]   High-performance liquid chromatography-tandem electrospray mass spectrometry for the determination of lidocaine and its metabolites in human plasma and urine [J].
Abdel-Rehim, M ;
Bielenstein, M ;
Askemark, Y ;
Tyrefors, N ;
Arvidsson, T .
JOURNAL OF CHROMATOGRAPHY B, 2000, 741 (02) :175-188
[4]  
Abdel-Rehim M, 2000, J MICROCOLUMN SEP, V12, P308, DOI 10.1002/(SICI)1520-667X(2000)12:5<308::AID-MCS5>3.0.CO
[5]  
2-F
[6]  
Arvidsson T, 1999, BIOMED CHROMATOGR, V13, P286, DOI 10.1002/(SICI)1099-0801(199906)13:4<286::AID-BMC862>3.0.CO
[7]  
2-M
[8]   Determination of ropivacaine and [2H3]ropivacaine in biological samples by gas chromatography with nitrogen-phosphorus detection or mass spectrometry [J].
Engman, M ;
Neidenström, P ;
Norsten-Höög, C ;
Wiklund, SJ ;
Bondesson, U ;
Arvidsson, T .
JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (01) :57-67
[9]  
FRITZ JS, 1999, ANAL SOLID PHASE EXT
[10]   Phenotype of CYP2C19 and CYP3A4 by determination of omeprazole and its two main metabolites in plasma using liquid chromatography with liquid-liquid extraction [J].
González, HM ;
Romero, EM ;
Chavez, TD ;
Peregrina, AA ;
Quezada, V ;
Hoyo-Vadillo, C .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02) :459-465