Emerging ultrasound technologies for early markers of disease

被引:8
作者
Feleppa, EJ
Alam, SK
Deng, CX
机构
[1] Riverside Res Inst, Biomed Engn Labs, New York, NY 10038 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH USA
关键词
D O I
10.1155/2002/167104
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 [微生物学]; 0836 [生物工程]; 090102 [作物遗传育种]; 100705 [微生物与生化药学];
摘要
Ultrasound has been a popular clinical imaging modality for decades. It is well established as a means of displaying the macroscopic anatomy of soft-tissue structures. While conventional ultrasound methodologies (i.e., B-mode and Doppler methods) are well proven and continue to advance technically on a daily basis, e.g. by extending into higher frequencies and taking advantage of harmonic phenomena in tissues, fundamentally new ultrasound technologies also are emerging and offer exciting promise for making significant improvements in the clinical imaging of disease. These emerging methods include spectrum analysis, elasticity imaging, contrast-agent methods, and advanced flow detection and measurement techniques. Each provides independent information and, used alone, each can provide powerful new imaging capabilities; combined with each other, their capabilities may be even greater in many applications; and all in principle can be used in concert with other imaging modalities to offer the possibility of further improvements in disease detection, evaluation, and monitoring.
引用
收藏
页码:249 / 268
页数:20
相关论文
共 156 条
[1]
Computer-aided diagnosis of breast lesions using a multifeature analysis procedure [J].
Alam, SK ;
Lizzi, FL ;
Feleppa, EJ ;
Liu, T ;
Kalisz, A .
MEDICAL IMAGE 2002: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2002, 4687 :296-303
[2]
Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching: Applications to elastography [J].
Alam, SK ;
Ophir, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (01) :95-105
[3]
An adaptive strain estimator for elastography [J].
Alam, SK ;
Ophir, J ;
Konofagou, EE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (02) :461-472
[4]
Elastographic axial resolution criteria: An experimental study [J].
Alam, SK ;
Ophir, J ;
Varghese, T .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :304-309
[5]
The effect of nonlinear signal transformations on bias errors in elastography [J].
Alam, SK ;
Ophir, J .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :297-303
[6]
ALAM SK, P SPIE, V4325, P314
[7]
Non-invasive diagnosis of hepatic cirrhosis by transit-time analysis of an ultrasound contrast agent [J].
Albrecht, T ;
Blomley, MJK ;
Cosgrove, DO ;
Taylor-Robinson, SD ;
Jayaram, V ;
Eckersley, R ;
Urbank, A ;
Butler-Barnes, J ;
Patel, N .
LANCET, 1999, 353 (9164) :1579-1583
[8]
[Anonymous], J ULTRASOUND MED
[9]
ASLANIDES IM, 1995, INVEST OPHTH VIS SCI, V36, pS564
[10]
Cloning, expression, genomic localization, and enzymatic activities of the mouse homolog of prostate-specific membrane antigen/NAALADase/folate hydrolase [J].
Bacich, DJ ;
Pinto, JT ;
Tong, WP ;
Heston, WDW .
MAMMALIAN GENOME, 2001, 12 (02) :117-123