Detection of 25,000 molecules of substance P by MALDI-TOF mass spectrometry and investigations into the fundamental limits of detection in MALDI

被引:55
作者
Keller, BO [1 ]
Li, L [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1016/S1044-0305(01)00288-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mass spectrometric analysis of peptides with a total sample loading of several tens of thousands of molecules (i.e., low zeptomoles) is demonstrated. At this low level of sample loading, it becomes important to consider several very unique technical and fundamental aspects that are not obvious in compatible experiments with a higher amount of sample loading. We demonstrate that prudent matrix preparation allows analysis of peptides from solutions with picomolar concentrations in matrix-assisted laser desorption ionization (MALDI) mass spectrometry. Using microspot MALDI we demonstrate the introduction and detection of 25,000 molecules of Substance P in a time-of-flight mass spectrometer. A method based on probability theory is presented to estimate the minimum number of ions required for generating a statistically significant isotope peak pattern of peptide ions. It is found that the low boundary of ionization efficiency is 1-2% for Substance P. In addition, comparison of macro- and microspot sample deposition techniques for Substance P shows that under the experimental conditions used, a minimum of similar to5 analyte molecules per mum(2) are necessary to generate useful signals. Implications of these results on further mass spectrometric developments towards even more sensitive detection are discussed. (C) 2001 American Society for Mass Spectrometry.
引用
收藏
页码:1055 / 1063
页数:9
相关论文
共 32 条
[1]  
Allmaier G, 1997, RAPID COMMUN MASS SP, V11, P1567, DOI 10.1002/(SICI)1097-0231(199709)11:14<1567::AID-RCM32>3.0.CO
[2]  
2-0
[3]   MICRO-ELECTROSPRAY - ZEPTOMOLE-ATTOMOLE PER MICROLITER SENSITIVITY FOR PEPTIDES [J].
ANDREN, PE ;
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (09) :867-869
[4]   Zeptomole-sensitivity electrospray ionization - Fourier transform ion cyclotron resonance mass spectrometry of proteins [J].
Belov, ME ;
Gorshkov, MV ;
Udseth, HR ;
Anderson, GA ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2271-2279
[5]  
CHEN CH, 1990, LASERS MASS SPECTROM, P6
[6]  
COTTER RJ, 1997, TIME OF FLIGHT MASS, P19
[7]   Detection of attomolar concentrations of alkaline phosphatase by capillary electrophoresis using laser-induced fluorescence detection [J].
Craig, DB ;
Wong, JCY ;
Dovichi, NJ .
ANALYTICAL CHEMISTRY, 1996, 68 (04) :697-700
[8]   Two-layer sample preparation: A method for MALDI-MS analysis of complex peptide and protein mixtures [J].
Dai, YQ ;
Whittal, RM ;
Li, L .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1087-1091
[9]  
DAI YQ, 1996, ANAL CHEM, V68, P2721
[10]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .