Fluorometric method for the enzymatic determination of cholesterol

被引:247
作者
Amundson, DM [1 ]
Zhou, MJ [1 ]
机构
[1] Mol Probes Inc, Eugene, OR 97402 USA
来源
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS | 1999年 / 38卷 / 01期
关键词
fluorescence; cholesterol; cholesterol oxidase; microplate; serum; Amplex (TM) Red reagent;
D O I
10.1016/S0165-022X(98)00036-0
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A fluorometric method for the enzymatic determination of cholesterol content has been developed using a novel fluorogenic H2O2 probe, Amplex Red. This assay is performed in a 96-well microplate, and it is a one-step method amenable to automated procedures. Using commercially available cholesterol, our assay allows detection of 5 pmol (2 ng) cholesterol per well, which is 100-fold more sensitive than published fluorometric and colorimetric methods. When applied to the measurement of cholesterol levels in serum and food samples, the Amplex Red-based method has been found more attractive since the oxidation product of the Amplex Red method has superior long wavelength spectra which are less susceptible to interference from the biological compounds. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 15 条
[1]
FLUOROMETRIC-DETERMINATION OF CHOLESTEROL USING AN OXIDASE-PEROXIDASE-RESORUFIN SYSTEM [J].
BROTEA, GP ;
DRAISEY, TF ;
THIBERT, RJ .
MICROCHEMICAL JOURNAL, 1989, 39 (01) :1-9
[2]
HIGH-SENSITIVE CHEMILUMINESCENT ASSAY FOR CHOLESTEROL [J].
CHAMOIN, MC ;
CHARBONNIER, M ;
LAFONT, H ;
TERNAUX, JP .
BIOCHIMICA ET BIOPHYSICA ACTA-LIPIDS AND LIPID METABOLISM, 1994, 1210 (02) :151-156
[3]
SENSITIVE ASSAY FOR CHOLESTEROL IN BIOLOGICAL-MEMBRANES REVEALS MEMBRANE-SPECIFIC DIFFERENCES IN KINETICS OF CHOLESTEROL OXIDASE [J].
CROCKETT, EL ;
HAZEL, JR .
JOURNAL OF EXPERIMENTAL ZOOLOGY, 1995, 271 (03) :190-195
[4]
GOTTSCHLING HD, 1995, EUR J CLIN CHEM CLIN, V33, P373
[5]
MICROENZYMATIC FLUORESCENCE ASSAY FOR SERUM-CHOLESTEROL [J].
GRAY, MC ;
PLANT, AL ;
NICHOLSON, JM ;
MAY, WE .
ANALYTICAL BIOCHEMISTRY, 1995, 224 (01) :286-292
[6]
Lolekha PH, 1996, J CLIN LAB ANAL, V10, P167, DOI 10.1002/(SICI)1098-2825(1996)10:4<167::AID-JCLA1>3.0.CO
[7]
2-7
[8]
LUHMAN CM, 1990, CLIN CHEM, V36, P331
[9]
A highly sensitive fluorescent micro-assay of H2O2 release from activated human leukocytes using a dihydroxyphenoxazine derivative [J].
Mohanty, JG ;
Jaffe, JS ;
Schulman, ES ;
Raible, DG .
JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 202 (02) :133-141
[10]
NAITO HK, 1984, CLIN CHEM, P1156