Simple method for estimating polychlorinated biphenyl concentrations on soils and sediments using subcritical water extraction coupled with solid-phase microextraction

被引:88
作者
Hawthorne, SB [1 ]
Grabanski, CB [1 ]
Hageman, KJ [1 ]
Miller, DJ [1 ]
机构
[1] Univ N Dakota, Energy & Environm Res Ctr, Grand Forks, ND 58202 USA
关键词
soil; sediments; environmental analysis; extraction methods; subcritical fluid extraction; polychlorinated biphenyls;
D O I
10.1016/S0021-9673(98)00418-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid method for estimating polychlorinated biphenyl (PCB) concentrations in contaminated soils and sediments has been developed by coupling static subcritical water extraction with solid-phase microextraction (SPME). Soil, water, and internal standards are placed in a sealed extraction cell, heated at 250 degrees C for 15 to 60 min, cooled, and the PCB concentrations in the extractant water determined by SPME and GC-electron-capture detection. When PCB 103 and 169 (not found in contaminated samples) are used as internal standards ro calibrate for the soil/water and water/SPME equilibria, quantitative results for individual PCB congeners typically agree within 80 to 130% of the concentrations based on Soxhlet extraction and conventional GC analysis. The reproducibility of replicate subcritical water extraction/SPME determinations is typically 10 to 15% relative standard deviation. Analysts of water extracts stored for 24 h agrees with fresh extracts, demonstrating that extracts can be stored for later SPME analysis without significant loss of the PCBs from the extractant water. The method is simple to perform, uses held-rugged and inexpensive apparatus, and generates no organic solvent waste. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:151 / 160
页数:10
相关论文
共 21 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]  
BOYDBOLAND AA, 1994, ENVIRON SCI TECHNOL, V28, P569
[3]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[4]  
ERICKSON MD, 1986, ANAL CHEM PCBS
[5]   Solid-phase microextraction for the analysis of human breath [J].
Grote, C ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :587-596
[6]   Coupled subcritical water extraction with solid-phase microextraction for determining semivolatile organics in environmental solids [J].
Hageman, KJ ;
Mazeas, L ;
Grabanski, CB ;
Miller, DJ ;
Hawthorne, SB .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3892-3898
[7]   Extraction of polychlorinated biphenyls with water under subcritical conditions [J].
Hartonen, K ;
Inkala, K ;
Kangas, M ;
Riekkola, ML .
JOURNAL OF CHROMATOGRAPHY A, 1997, 785 (1-2) :219-226
[8]   EXTRACTION OF ORGANIC POLLUTANTS FROM ENVIRONMENTAL SOLIDS WITH SUBCRITICAL AND SUPERCRITICAL WATER [J].
HAWTHORNE, SB ;
YANG, Y ;
MILLER, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2912-2920
[9]   Optimizing split/splitless injection port parameters for solid-phase microextraction [J].
Langenfeld, JJ ;
Hawthorne, SB ;
Miller, DJ .
JOURNAL OF CHROMATOGRAPHY A, 1996, 740 (01) :139-145
[10]   Quantitative analysis of fuel-related hydrocarbons in surface water and wastewater samples by solid-phase microextraction [J].
Langenfeld, JJ ;
Hawthorne, SB ;
Miller, DJ .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :144-155