Scanning transmission x-ray microscopy with a configurable detector

被引:106
作者
Gianoncelli, A.
Morrison, G. R.
Kaulich, B.
Bacescu, D.
Kovac, J.
机构
[1] Kings Coll London, Dept Phys, London WC2R 2LS, England
[2] Sincrotrone Trieste, I-34012 Trieste, Italy
[3] Jozef Stefan Inst, Ljubljana 1000, Slovenia
关键词
D O I
10.1063/1.2422908
中图分类号
O59 [应用物理学];
学科分类号
摘要
A configurable charge-coupled-device (CCD) detector is used in a scanning transmission x-ray microscope to record the transmitted intensity distribution for every pixel in a raster scan of the sample. Real-time processing of the CCD frames gives simultaneous absorption and phase contrast image signals from a single scan. The CCD combines fast frame-transfer readout with very high sensitivity and makes use of x-ray to visible-light coupling to allow operation over a wide range of photon energies, from the oxygen K edge upwards. Tests on the Twinmic end station at the Elettra synchrotron are reported. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 21 条
[1]   CHEMICAL CONTRAST IN X-RAY MICROSCOPY AND SPATIALLY RESOLVED XANES SPECTROSCOPY OF ORGANIC SPECIMENS [J].
ADE, H ;
ZHANG, X ;
CAMERON, S ;
COSTELLO, C ;
KIRZ, J ;
WILLIAMS, S .
SCIENCE, 1992, 258 (5084) :972-975
[2]   Re-evaluation of differential phase contrast (DPC) in a scanning laser microscope using a split detector as an alternative to differential interference contrast (DIC) optics [J].
Amos, WB ;
Reichelt, S ;
Cattermole, DM ;
Laufer, J .
JOURNAL OF MICROSCOPY, 2003, 210 :166-175
[3]   Soft X-ray microscopy at a spatial resolution better than 15nm [J].
Chao, WL ;
Harteneck, BD ;
Liddle, JA ;
Anderson, EH ;
Attwood, DT .
NATURE, 2005, 435 (7046) :1210-1213
[4]   X-RAY IMAGE-CONTRAST FROM A SIMPLE PHASE OBJECT [J].
DAVIS, TJ ;
GUREYEV, TE ;
GAO, D ;
STEVENSON, AW ;
WILKINS, SW .
PHYSICAL REVIEW LETTERS, 1995, 74 (16) :3173-3176
[5]   Scanning transmission X-ray microscopy with a segmented detector [J].
Feser, M ;
Jacobsen, C ;
Rehak, P ;
DeGeronimo, G .
JOURNAL DE PHYSIQUE IV, 2003, 104 :529-534
[6]   Integrating Silicon detector with segmentation for scanning transmission X-ray microscopy [J].
Feser, Michael ;
Hornberger, Benjamin ;
Jacobsen, Chris ;
De Geronimo, Gianluigi ;
Rehak, Pavel ;
Holl, Peter ;
Strueder, Lothar .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (02) :841-854
[7]  
Howells, 2006, SCI MICROSCOPY, P835, DOI [10.1016/s1369-7021(06)71581-4, DOI 10.1016/S1369-7021(06)71581-4]
[8]   Excess noise and other important characteristics of low light level imaging using charge multiplying CCDs [J].
Hynecek, J ;
Nishiwaki, T .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2003, 50 (01) :239-245
[9]  
Kaulich A., 2006, P 8 INT C XRAY MICR, V7, P22
[10]   X-ray tomography generates 3-D reconstructions of the yeast, Saccharomyces cerevisiae, at 60-nm resolution [J].
Larabell, CA ;
Le Gros, MA .
MOLECULAR BIOLOGY OF THE CELL, 2004, 15 (03) :957-962