Transmission-based scatter correction of 180 degrees myocardial single-photon emission tomographic studies

被引:31
作者
Hutton, BF [1 ]
Osiecki, A [1 ]
Meikle, SR [1 ]
机构
[1] ROYAL PRINCE ALFRED HOSP, DEPT NUCL MED, SYDNEY, NSW, AUSTRALIA
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1996年 / 23卷 / 10期
关键词
myocardial single-photon emission tomography; scatter correction; 180 degrees acquisition; quantification; transmission-based correction;
D O I
10.1007/BF01367584
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Meaningful comparison of single-photon emission tomographic (SPET) reconstructions for data acquired over 180 degrees or 360 degrees can only be performed if both attenuation and scatter correction are applied, Convolution subtraction has appeal as a practical method for scatter correction; however, it is limited to data acquired over 360 degrees, A new algorithm is proposed which can be applied equally well to data acquired over 180 degrees or 360 degrees The method involves estimating scatter based on knowledge of reconstructed transmission data in combination with a reconstructed estimate of the activity distribution, obtained using attenuation correction with broad beam attenuation coefficients, Processing is implemented for planes of activity parallel to the projection images for which a simplified model for the scatter distribution may be applied, based on the measured attenuation. The appropriate broad beam (effective) attenuation coefficients were determined by considering the scatter buildup equation. It was demonstrated that narrow beam attenuation coefficients should be scaled by 0.75 and 0.65 to provide broad beam attenuation coefficients for technetium-99m and thallium-201 respectively. Using a thorax phantom, quantitative accuracy of the new algorithm was compared with conventional transmission-based convolution subtraction (TDCS) for 360 degrees data, Similar heart to lung contrasts were achieved and correction of 180 degrees data yielded a 10.4% error for cardiac activity compared to 5.2% for TDCS, Contrast for myocardium to ventricular cavity was similarly good for scatter-corrected 180 degrees and 360 degrees data, in contrast to attenuation-corrected data, where contrast was significantly reduced, The new algorithm provides a practical method for correction of scatter applicable to 180 degrees myocardial SPET.
引用
收藏
页码:1300 / 1308
页数:9
相关论文
共 40 条
[1]  
AXELSSON B, 1984, J NUCL MED, V25, P490
[2]   STUDIES OF A TECHNIQUE FOR ATTENUATION CORRECTION IN SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY [J].
AXELSSON, B ;
ISRAELSSON, A ;
LARSSON, SA .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (06) :737-749
[3]  
BAILEY DL, 1987, J NUCL MED, V28, P844
[4]   OBJECT SHAPE DEPENDENT PSF MODEL FOR SPECT IMAGING [J].
BEEKMAN, FJ ;
EIJKMAN, EGJ ;
VIERGEVER, MA ;
BORM, GF ;
SLIJPEN, ETP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (01) :31-39
[5]   SCATTER CORRECTION IN SCINTIGRAPHY - THE STATE-OF-THE-ART [J].
BUVAT, I ;
BENALI, H ;
TODDPOKROPEK, A ;
DIPAOLA, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (07) :675-694
[7]   APPLICATION OF CONVERGENT-BEAM COLLIMATION AND SIMULTANEOUS TRANSMISSION EMISSION TOMOGRAPHY TO CARDIAC SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY [J].
DATZ, FL ;
GULLBERG, GT ;
ZENG, GSL ;
TUNG, CH ;
CHRISTIAN, PE ;
WELCH, A ;
CLACK, R .
SEMINARS IN NUCLEAR MEDICINE, 1994, 24 (01) :17-37
[8]  
FICARO EP, 1995, J NUCL MED, V36, P921
[10]   PARAMETERIZATION OF THE SCATTER RESPONSE FUNCTION IN SPECT IMAGING USING MONTE-CARLO SIMULATION [J].
FREY, EC ;
TSUI, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (03) :1308-1315