Using skin temperature gradients or skin heat flux measurements to determine thresholds of vasoconstriction and vasodilatation

被引:88
作者
House, JR [1 ]
Tipton, MJ
机构
[1] Inst Naval Med, Environm Med Unit, Gosport PO12 2DL, Hants, England
[2] Univ Portsmouth, Dept Exercise & Sport Sci, Inst Biomed & Biomol Sci, Portsmouth PO1 2DT, Hants, England
关键词
laser-Doppler flowmetry; skin temperature; vasomotricity; skin temperature differentials;
D O I
10.1007/s00421-002-0692-3
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Forearm-fingertip skin temperature differentials (Tsk-diff) are used to indicate vasomotor tone, vasoconstriction defined as having occurred when Tsk-diff greater than or equal to4degreesC (Sessler et al. 1987, 1988a, b). This study was conducted to determine whether Tsk-diff or finger pad heat flux (HF) can be used to predict when vasoconstriction and vasodilatation occur. Seven subjects (one female) sat in water at [mean (SD)] 40.7 (0.8)degreesC until their core temperature (T,) increased by 1degreesC, ensuring vasodilatation. The water was then cooled [at a rate of 0.6 (0.1)degreesC.min(-1)] until T-c fell to 0.5degreesC below pretesting values, causing vasoconstriction. Subjects were then rewarmed in water [41.2 (1.0)degreesC]. Skin blood flow (SkBF) was measured using laser Doppler flowmetry (LDF) on the left second finger pad [immersed in water at 10.4 (1.4)degreesC as part of another experiment], and infrared plethysmography on the third finger pad of both hands. Tsk-diff and HF were measured on the right upper limb, which remained in air. When vasodilated, the subjects had a stable Tsk-diff and HE During cooling, rapid-onset vasoconstriction occurred coincidental with large gradient changes in HF and Tsk-diff (inflection points). In two subjects the original vasoconstriction definition (Tsk-diff greater than or equal to4degreesC) was not attained, in the other five this was achieved 31-51 min after vasoconstriction. During rewarming, the Tsk-diff and HF inflection points less accurately reflected the onset of vasodilatation, although with one exception they were within 5 min of the LDF changes. We conclude that Tsk-diff and HF inflection points predict vasoconstriction accurately, and better than Tsk-diff greater than or equal to4degreesC.
引用
收藏
页码:141 / 145
页数:5
相关论文
共 14 条
[1]   EVALUATION OF CUTANEOUS BLOOD-FLOW RESPONSES BY XE-133 WASHOUT AND A LASER-DOPPLER FLOWMETER [J].
ENGELHART, M ;
KRISTENSEN, JK .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1983, 80 (01) :12-15
[2]   OBSERVATIONS OF A LASER DOPPLER FLOWMETER OUTPUT MADE USING A CALIBRATION STANDARD [J].
FAIRS, SLE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (04) :404-406
[3]  
FLACKE JW, 1983, SEMIN ANESTH, V2, P183
[5]   ASPECTS OF LASER-LIGHT SCATTERING FROM SKIN TISSUE WITH APPLICATION TO LASER DOPPLER BLOOD-FLOW MEASUREMENT [J].
GUSH, RJ ;
KING, TA ;
JAYSON, MIV .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (12) :1463-1476
[6]   TREATMENT OF SHOCK WITH VASODILATORS MEASURING SKIN TEMPERATURE ON BIG TOE - 10 YEARS EXPERIENCE IN 150 CASES [J].
IBSEN, B .
DISEASES OF THE CHEST, 1967, 52 (04) :425-&
[7]   LASER-DOPPLER MEASUREMENT OF SKIN BLOOD-FLOW - COMPARISON WITH PLETHYSMOGRAPHY [J].
JOHNSON, JM ;
TAYLOR, WF ;
SHEPHERD, AP ;
PARK, MK .
JOURNAL OF APPLIED PHYSIOLOGY, 1984, 56 (03) :798-803
[8]  
OAKLEY EHN, 1994, PROGR MICROCIRCULATI, P493
[9]  
SESSLER D I, 1987, Anesthesiology (Hagerstown), V67, pA405, DOI 10.1097/00000542-198709001-00405
[10]   THE THERMOREGULATORY THRESHOLD IN HUMANS DURING HALOTHANE ANESTHESIA [J].
SESSLER, DI ;
OLOFSSON, CI ;
RUBINSTEIN, EH ;
BEEBE, JJ .
ANESTHESIOLOGY, 1988, 68 (06) :836-842