How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint

被引:210
作者
Donahue, TLH
Hull, ML
Rashid, MM
Jacobs, CR
机构
[1] Michigan Technol Univ, Dept Mech Engn Engn Mech, Houghton, MI 49931 USA
[2] Univ Calif Davis, Biomed Engn Program, Davis, CA 95616 USA
[3] Univ Calif Davis, Dept Mech Engn, Davis, CA 95616 USA
[4] Univ Calif Davis, Dept Civil Engn, Davis, CA 95616 USA
[5] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
关键词
meniscus; contact; finite element method; material properties; knee;
D O I
10.1016/S0021-9290(02)00305-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements are subjects of current interest and investigation. The objectives of the current study were to (1) determine whether a transversely isotropic, linearly elastic, homogeneous material model of the meniscal tissue is necessary to achieve a normal contact pressure distribution on the tibial plateau, (2) determine which material and boundary condition (attachments) parameters affect the contact pressure distribution most strongly, and (3) set tolerances on these parameters to restore the contact pressure distribution to within a specified error. To satisfy these objectives, a finite element model of the tibio-femoral joint of a human cadaveric knee (including both menisci) was used to study the contact pressure distribution on the tibial plateau. To validate the model, the contact pressure distribution on the tibial plateau was measured experimentally in the same knee used to create the model. Within physiologically reasonable bounds on five material parameters and four attachment parameters associated with a meniscal replacement, an optimization was performed under 1200 N of compressive load on the set of nine parameters to minimize the difference between the experimental and model results. The error between the experimental and model contact variables was minimized to 5.4%. The contact pressure distribution of the tibial plateau was sensitive to the circumferential modulus, axial/radial modulus, and horn stiffness, but relatively insensitive to the remaining six parameters. Consequently, both the circumferential and axial/radial moduli are important determinants of the contact pressure distribution, and hence should be matched in the design and/ or selection of meniscal replacements. In addition, during surgical implantation of a meniscal replacement, the horns should be attached with high stiffness bone plugs, and the attachments of the transverse ligament and deep medial collateral ligament should be restored to minimize changes in the contact pressure distribution, and thereby possibly prevent the degradation of articular cartilage. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:19 / 34
页数:16
相关论文
共 62 条
[1]
INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .1. TIBIAL SURFACE OF THE KNEE [J].
AHMED, AM ;
BURKE, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :216-225
[2]
How three methods for fixing a medial meniscal autograft affect tibial contact mechanics [J].
Alhalki, MM ;
Howell, SM ;
Hull, ML .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (03) :320-328
[3]
LATE DEGENERATIVE CHANGES AFTER MENISCECTOMY - FACTORS AFFECTING THE KNEE AFTER OPERATION [J].
ALLEN, PR ;
DENHAM, RA ;
SWAN, AV .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (05) :666-671
[4]
[Anonymous], 1987, INJURY REPAIR MUSCUL
[5]
[Anonymous], 1984, ASME ADV BIOENG
[6]
[Anonymous], BASIC ORTHOPAEDIC BI
[7]
[Anonymous], 1989, T ORTHOP RES SOC
[8]
THE EFFECT OF CRYOPRESERVATION ON CANINE MENISCI - A BIOCHEMICAL, MORPHOLOGIC, AND BIOMECHANICAL EVALUATION [J].
ARNOCZKY, SP ;
MCDEVITT, CA ;
SCHMIDT, MB ;
MOW, VC ;
WARREN, RF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (01) :1-12
[9]
ARNOCZKY SP, 1990, CLIN ORTHOP RELAT R, V252, P121
[10]
A STEREOPHOTOGRAMMETRIC METHOD FOR DETERMINING IN-SITU CONTACT AREAS IN DIARTHROIDAL JOINTS, AND A COMPARISON WITH OTHER METHODS [J].
ATESHIAN, GA ;
KWAK, SD ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :111-124