Do left ventricular assist device (LVAD) bridge-to-transplantation outcomes predict the results of permanent LVAD implantation?

被引:42
作者
Navia, JL
Mccarthy, PM
Hoercher, KJ
Smedira, NG
Banbury, MK
Blackstone, EH
机构
[1] Cleveland Clin Fdn, Dept Thorac & Cardiovasc Surg, Kaufman Ctr Heart Failure, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Biostat & Epidemiol, Cleveland, OH 44195 USA
关键词
D O I
10.1016/S0003-4975(02)04084-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Implantable left ventricular assist devices (LVADs) were designed for permanent implant, but we began their use for bridge-to-transplant (BTTx) to study their safety and effectiveness. We review our experience in order to compare the BTTx lessons learned with the outcomes and goals of permanent implants. Methods. From December 1991 until January 2002, 264 patients received 277 LVADs for BTTx. We analyzed temporal trends in pre-LVAD patient factors and device-specific time-related complications. Results. Survival to transplant was 69%. Adverse event analysis demonstrated a high risk of infections (0.56,1.28, and 1.88 per patient at 30 days and 3 and 6 months). HeartMate devices were more prone to infection than Novacor devices (p < 0.0001). Cerebral infarctions occurred less commonly than infections (0.15, 0.25, 0.30 at 30 days and 3 and 6 months), were more common in Novacor than HeartMate (p = 0.0001), and were decreased by the new Novacor Vascutek conduit (p = 0.07), but these were still slightly higher than the HeartMate (p = 0.04). Device failures occurred in 21 instances (all but one were in HeartMate devices [p = 0.04 vs Novacor]), but have significantly decreased (p < 0.0001) in HeartMate since 1998. Conclusions. Infections and device durability limit the chronic use of the HeartMate device, but device failures are decreasing. Novacor has fewer problems with infection and durability, and the new Vascutek conduit will reduce, but not eliminate, strokes.
引用
收藏
页码:2051 / 2062
页数:12
相关论文
共 21 条
[1]  
Andersen PK., 1993, STAT MODELS BASED CO, P176
[2]  
BASKERVILLE JC, 1982, TECHNOMETRICS, V24, P9
[3]   THE DECOMPOSITION OF TIME-VARYING HAZARD INTO PHASES, EACH INCORPORATING A SEPARATE STREAM OF CONCOMITANT INFORMATION [J].
BLACKSTONE, EH ;
NAFTEL, DC ;
TURNER, ME .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1986, 81 (395) :615-624
[4]   Competing risks after coronary bypass surgery: The influence of death on reintervention [J].
Blackstone, EH ;
Lytle, BW .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (06) :1221-1230
[5]   Random forests [J].
Breiman, L .
MACHINE LEARNING, 2001, 45 (01) :5-32
[7]  
Frazier O H., 2001, J Heart Lung Transplant, V20, P201
[8]   MULTICENTER CLINICAL-EVALUATION OF THE HEARTMATE 1000-IP LEFT-VENTRICULAR ASSIST DEVICE [J].
FRAZIER, OH ;
ROSE, EA ;
MACMANUS, Q ;
BURTON, NA ;
LEFRAK, EA ;
POIRIER, VL ;
DASSE, KA .
ANNALS OF THORACIC SURGERY, 1992, 53 (06) :1080-1090
[9]   Nosocomial bloodstream infections in patients with implantable left ventricular assist devices [J].
Gordon, SM ;
Schmitt, SK ;
Jacobs, M ;
Smedira, NM ;
Goormastic, M ;
Banbury, MK ;
Yeager, M ;
Serkey, J ;
Hoercher, K ;
McCarthy, PM .
ANNALS OF THORACIC SURGERY, 2001, 72 (03) :725-730
[10]   Comparison of functional capacity in patients with end-stage heart failure following implantation of a left ventricular assist device versus heart transplantation:: Results of the experience with left ventricular assist device with exercise trial [J].
Jaski, BE ;
Lingle, RJ ;
Kim, J ;
Branch, KR ;
Goldsmith, R ;
Johnson, MR ;
Lahpor, JR ;
Icenogle, TB ;
Piña, I ;
Adamson, R ;
Favrot, LK ;
Dembitsky, WP .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1999, 18 (11) :1031-1040