Wall shear stress in the human common carotid artery as function of age and gender

被引:143
作者
Samijo, SK
Willigers, JM
Barkhuysen, R
Kitslaar, PJEHM
Reneman, RS
Brands, PJ
Hoeks, APG
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht, Dept Biophys, NL-6200 MD Maastricht, Netherlands
[2] Maastricht Univ, Cardiovasc Res Inst Maastricht, Dept Surg, NL-6200 MD Maastricht, Netherlands
[3] Maastricht Univ, Cardiovasc Res Inst Maastricht, Dept Physiol, NL-6200 MD Maastricht, Netherlands
关键词
ageing; blood flow; carotid artery; gender; ultrasound; wall shear rate; wall shear stress;
D O I
10.1016/S0008-6363(98)00074-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: It has been postulated that in the arterial system mean wall shear stress is maintained at a constant value. The present study was performed to investigate the level of wall shear stress in the common carotid artery (CCA) as function of age and possible interactions between diameter and storage capacity, defined as the absolute area change per heart beat, with mean wall shear stress. Methods: Wall shear stress (wall shear rate multiplied by whole blood viscosity) was assessed in the right CCA of III presumed healthy male (n = 56) and female (n = 55) volunteers, varying in age between 10 and 60 years. Wall shear rate was measured with a high resolution ultrasound system. Simultaneously, arterial diameter and storage capacity were determined. Whole blood viscosity was calculated from haematocrit, plasma viscosity and shear rate. Results: From the second to the sixth age decade peak wall shear stress was significantly higher in males than in females and decreased from 4.3 Pa to 2.6 Pa (r=-0.56, p<0.001) in males and from 3.3 Pa to 2.5 Pa (r=-0.54, p<0.001) in females. Mean wall shear stress tended to decrease from 1.5 Pa to 1.2 Pa (r=-0.26, p=0.057) in males and decreased significantly from 1.3 Pa to 1.1 Pa (r=-0.30, p=0.021) in females. No significant difference in mean wall shear stress was found between males and females in any age decade. The diameter of the CCA increased significantly in both males (r=0.26, p<0.05) and females (r=0.40, p<0.003). Storage capacity decreased significantly in both sexes (males: r=-0.63, p<0.001; females: r=-0.68, p<0.001), Conclusions: These observations suggest that the reduction in mean wall shear stress with age results from the concomitant increase in diameter in an attempt of the arterial system to limit the reduction in storage capacity of the arterial system with increasing age. (C) 1998 Elsevier Science B,V. All rights reserved.
引用
收藏
页码:515 / 522
页数:8
相关论文
共 42 条
[1]  
ALTMAN DG, 1994, PRACTICAL STAT MED R, P336
[2]   CHANGES IN CAROTID-ARTERY COMPLIANCE WITH AGE [J].
BASKETT, JJ ;
LEWIS, RR ;
BEASLEY, MG ;
GOSLING, RG .
AGE AND AGEING, 1990, 19 (04) :241-246
[3]   THE EFFECT OF ECHO SUPPRESSION ON THE MEAN VELOCITY ESTIMATION RANGE OF THE RF CROSS-CORRELATION MODEL ESTIMATOR [J].
BRANDS, PJ ;
HOEKS, APG ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (07) :945-959
[4]   A NONINVASIVE METHOD TO ESTIMATE WALL SHEAR RATE USING ULTRASOUND [J].
BRANDS, PJ ;
HOEKS, APG ;
HOFSTRA, L ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (02) :171-185
[5]  
Caro C.G., 1971, P R SOC LOND B, V177, P105
[6]   RELATION OF BLOOD-VISCOSITY TO DEMOGRAPHIC AND PHYSIOLOGIC VARIABLES AND TO CARDIOVASCULAR RISK-FACTORS IN APPARENTLY NORMAL ADULTS [J].
DESIMONE, G ;
DEVEREUX, RB ;
CHIEN, S ;
ALDERMAN, MH ;
ATLAS, SA ;
LARAGH, JH .
CIRCULATION, 1990, 81 (01) :107-117
[7]   THE EFFECT OF COMPLIANCE ON WALL SHEAR IN CASTS OF A HUMAN AORTIC BIFURCATION [J].
DUNCAN, DD ;
BARGERON, CB ;
BORCHARDT, SE ;
DETERS, OJ ;
GEARHART, SA ;
MARK, FF ;
FRIEDMAN, MH .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (02) :183-188
[8]   EFFECTS OF AGE ON ENDOTHELIUM-DEPENDENT VASODILATION OF RESISTANCE CORONARY-ARTERY BY ACETYLCHOLINE IN HUMANS [J].
EGASHIRA, K ;
INOU, T ;
HIROOKA, Y ;
KAI, H ;
SUGIMACHI, M ;
SUZUKI, S ;
KUGA, T ;
URABE, Y ;
TAKESHITA, A .
CIRCULATION, 1993, 88 (01) :77-81
[9]   FLOW EFFECTS ON PROSTACYCLIN PRODUCTION BY CULTURED HUMAN-ENDOTHELIAL CELLS [J].
FRANGOS, JA ;
ESKIN, SG ;
MCINTIRE, LV ;
IVES, CL .
SCIENCE, 1985, 227 (4693) :1477-1479
[10]   CORRELATION BETWEEN INTIMAL THICKNESS AND FLUID SHEAR IN HUMAN ARTERIES [J].
FRIEDMAN, MH ;
HUTCHINS, GM ;
BARGERON, CB ;
DETERS, OJ ;
MARK, FF .
ATHEROSCLEROSIS, 1981, 39 (03) :425-436