A dynamic voltage restorer (DVR) with selective harmonic compensation at medium voltage level

被引:128
作者
Newman, MJ
Holmes, DG
Nielsen, JG
Blaabjerg, F
机构
[1] Monash Univ, Dept Elect & Comp Syst Engn, Clayton, Vic 3800, Australia
[2] Vestas Wind Syst, DK-8900 Randers, Denmark
[3] Aalborg Univ, Inst Energy Technol, DK-9220 Aalborg, Denmark
基金
澳大利亚研究理事会;
关键词
active filter; dynamic voltage restorer; harmonics; medium voltage; series transformer; stationary frame control;
D O I
10.1109/TIA.2005.858212
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Dynamic voltage restorers (DVRs) are now becoming more established in industry to reduce the impact of voltage sags to sensitive loads. However, DVRs spend most of their time in standby mode, since voltage sags occur very infrequently, and hence their utilization is low. In principle, it would be advantageous if the series-connected inverter of a DVR could also be used to compensate for any steady-state load voltage harmonics, since this would increase the power quality "value-added" benefits to the grid system. However, before this can be done, consideration must be given to the control of steady-state power through the DVR, the increased losses, and the low modulation depths at which the scheme must operate to achieve acceptable harmonic compensation performance. This paper presents a selective harmonic feedback control strategy that can be easily added to medium-voltage DVR systems to provide voltage harmonic compensation capabilities with minimal effect on the sag compensation performance of the basic DVR. The proposed controller has been experimentally verified on a medium-voltage (10 kV) three-phase DVR prototype under a range of conditions, including distorted supply voltages, nonlinear loads, and operation during distorted voltage sags.
引用
收藏
页码:1744 / 1753
页数:10
相关论文
共 8 条
[2]  
Newman MJ, 2002, IEEE IND ELEC, P1261, DOI 10.1109/IECON.2002.1185456
[3]   A detailed comparison of system topologies for dynamic voltage restorers [J].
Nielsen, JG ;
Blaabjerg, F .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) :1272-1280
[4]  
NIELSEN JG, 2002, THESIS AALBORG U AAL
[5]  
Sannino A, 2002, 2002 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, P1147, DOI 10.1109/PESW.2002.985189
[6]  
Stump MD, 1998, IEEE CONF R, P507, DOI 10.1109/EMPD.1998.702726
[7]   Experience with an inverter-based Dynamic Voltage Restorer [J].
Woodley, NH ;
Morgan, L ;
Sundaram, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (03) :1181-1186
[8]   Frequency-domain analysis of three-phase linear current regulators [J].
Zmood, DN ;
Holmes, DG ;
Bode, GH .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (02) :601-610