Fracture of the femoral component associated with polyethylene wear and osteolysis after total knee arthroplasty

被引:41
作者
Huang, CH [1 ]
Yang, CY [1 ]
Cheng, CK [1 ]
机构
[1] Mackay Mem Hosp, Dept Orthopaed Surg, Taipei, Taiwan
关键词
polyethylene wear; fracture of femoral component; osteolysis; total knee arthroplasty;
D O I
10.1016/S0883-5403(99)90066-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fracture of the femoral component associated with polyethylene wear and osteolysis after total knee arthroplasty (TKA) has not been well reported before. A 63-year-old man with osteoarthritis of the right knee underwent TKA with a New Jersey LCS Knee, with cementing on the tibia and patella but not on the femoral component. After 42 months, in addition to wearing of polyethylene of the tibia and patella, severe osteonecrosis of the medial femoral condyle was noted. Osteonecrosis caused loss of osseous support of the medial flan,ae of the femoral component, and the bone ingrowth of the central and lateral flange to the distal femur was so good chat it overcame the yield stress of the metal df the femoral component and caused fracture of the femoral component. The osteolytic area was filled with autogenous iliac bone, and a new femoral component was inserted and cemented. The patient's condition became satisfactory with relief of pain. Although uncommon, fracture of the femoral component does occur associated with polyethylene wear and osteolysis.
引用
收藏
页码:375 / 379
页数:5
相关论文
共 44 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]   LOCALIZED ENDOSTEAL BONE LYSIS IN RELATION TO THE FEMORAL COMPONENTS OF CEMENTED TOTAL HIP ARTHROPLASTIES [J].
ANTHONY, PP ;
GIE, GA ;
HOWIE, CR ;
LING, RSM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06) :971-979
[3]  
BERRY DJ, 1993, CLIN ORTHOP RELAT R, P204
[4]   METALLOSIS ASSOCIATED WITH A STABLE TITANIUM-ALLOY FEMORAL COMPONENT IN TOTAL HIP-REPLACEMENT - A CASE-REPORT [J].
BLACK, J ;
SHERK, H ;
BONINI, J ;
ROSTOKER, WR ;
SCHAJOWICZ, F ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (01) :126-130
[5]   THE NEW-JERSEY LOW-CONTACT-STRESS KNEE REPLACEMENT SYSTEM - BIOMECHANICAL RATIONALE AND REVIEW OF THE 1ST 123 CEMENTED CASES [J].
BUECHEL, FF ;
PAPPAS, MJ .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 105 (04) :197-204
[6]  
Cameron H U, 1990, J Arthroplasty, V5, P315, DOI 10.1016/S0883-5403(08)80089-7
[7]   LOCALIZED BONE-RESORPTION IN THE FEMUR IN MECHANICAL FAILURE OF CEMENTED TOTAL HIP ARTHROPLASTIES [J].
CARLSSON, AS ;
GENTZ, CF ;
LINDER, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1983, 54 (03) :396-402
[8]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, P232
[9]   FATIGUE FAILURE OF NONCEMENTED POROUS-COATED IMPLANTS - A RETRIEVAL STUDY [J].
COOK, SD ;
THOMAS, KA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :20-24
[10]  
DEVANE PA, 1995, CLIN ORTHOP RELAT R, P303