Stress analysis of the disc adjacent to interbody fusion in lumbar spine

被引:103
作者
Chen, CS
Cheng, CK
Liu, CL
Lo, WH
机构
[1] Natl Yang Ming Univ, Orthopaed Biomech Lab, Inst Biomed Engn, Taipei 112, Taiwan
[2] Vet Gen Hosp, Dept Orthopaed Surg, Taipei, Taiwan
关键词
disc degeneration; finite element model; anterior interbody fusion;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
After anterior interbody fusion in the lumbar spine, the accelerated degeneration of the disc adjacent to the fusion levels was clinically observed. To understand the stress distribution of the adjacent disc, this study created a finite element model of the lumbar spine from L1-L5 vertebral body. The fusion model modified from the intact model was used to simulate the anterior interbody fusion. Various loading conditions, which included flexion, extension, lateral bending, and torsion, were applied to the finite element model to study the corresponding stress distribution. From the finite element model calculation, at a lower fusion site or more fusion levels, the stress of the disc adjacent to interbody fusion increased more than upper fusion site or single fusion level under flexion, torsion and lateral bending. Larger stress increase was estimated at the upper disc adjacent to interbody fusion than the lower disc adjacent to interbody fusion. In stress distribution, the upper disc adjacent to interbody fusion had a little alteration under torsion. (C) 2001 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:483 / 491
页数:9
相关论文
共 28 条
[1]
FRYMOYER J W, 1978, Spine, V3, P1, DOI 10.1097/00007632-197803000-00001
[2]
COMPARISON OF RADIOGRAPHIC FINDINGS IN FUSION AND NON-FUSION PATIENTS 10 OR MORE YEARS FOLLOWING LUMBAR-DISK SURGERY [J].
FRYMOYER, JW ;
HANLEY, EN ;
HOWE, J ;
KUHLMANN, D ;
MATTERI, RE .
SPINE, 1979, 4 (05) :435-440
[3]
AN ANALYTICAL INVESTIGATION OF THE MECHANICS OF SPINAL INSTRUMENTATION [J].
GOEL, VK ;
KIM, YE ;
LIM, TH ;
WEINSTEIN, JN .
SPINE, 1988, 13 (09) :1003-1011
[4]
INTERLAMINAR SHEAR STRESSES AND LAMINAE SEPARATION IN A DISC - FINITE-ELEMENT ANALYSIS OF THE L3-L4 MOTION SEGMENT SUBJECTED TO AXIAL COMPRESSIVE LOADS [J].
GOEL, VK ;
MONROE, BT ;
GILBERTSON, LG ;
BRINCKMANN, P ;
NAT, R .
SPINE, 1995, 20 (06) :689-698
[5]
GOEL VK, 1993, SPINE, V18, P1531
[6]
Prediction of load sharing among spinal components of a C5-C6 motion segment using the finite element approach [J].
Goel, VK ;
Clausen, JD .
SPINE, 1998, 23 (06) :684-691
[7]
INOUE SI, 1988, CLIN ORTHOP RELAT R, P90
[8]
EFFECT OF DISK DEGENERATION AT ONE LEVEL ON THE ADJACENT LEVEL IN AXIAL MODE [J].
KIM, YE ;
GOEL, VK ;
WEINSTEIN, JN ;
LIM, TH .
SPINE, 1991, 16 (03) :331-335
[9]
Kim YE., 1988, THESIS U IOWA IOWA C
[10]
Motion in lumbar functional spine units during side bending and axial rotation moments depending on the degree of degeneration [J].
Krismer, M ;
Haid, C ;
Behensky, H ;
Kapfinger, P ;
Landauer, F ;
Rachbauer, F .
SPINE, 2000, 25 (16) :2020-2027