Role of microstructure on contact damage and strength degradation of micaceous glass-ceramics

被引:78
作者
Peterson, IM [1 ]
Wuttiphan, S
Lawn, BR
Chyung, K
机构
[1] Natl Inst Stand & Technol, Mat Sci & Engn Lab, Gaithersburg, MD 20899 USA
[2] Corning Inc, Glass & Glass Ceram Res, Corning, NY 14831 USA
关键词
D O I
10.1016/S0109-5641(98)00013-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. This study examines the hypothesis that microstructure plays a critical role in the accumulation of strength-degrading damage in dental ceramics. A series of micaceous glass-ceramics crystallized from a common glass composition, using heat treatments to increase the diameter and aspect ratio of mica platelets, is used as a model ceramic system. Methods. Damage modes are investigated by Hertzian contact testing. Four-point bend tests on indented specimens quantify the influence of single-cycle and multi-cycle damage on strength. Results. Two competing damage modes are observed: fracture, by tensile-induced cone cracking at the macroscopic level; and quasi-plastic deformation, by shear-induced yield at the microscopic level. The quasi-plastic mode becomes more dominant as the microstructures become coarser and more elongate. Bend tests show severe strength losses in the finer grain structures where cone cracking dominates, but relatively small losses in the coarser grain structures where quasi-plasticity dominates. Whereas natural strengths decline with increasing crystallization temperature, the strengths after indentation damage attain a maximum at intermediate crystallization temperatures. Multiple-cycle contact loading reduces strengths even further, and at relatively tow indentation loads, indicating susceptibility to fatigue. Finite element modelling is carried out to evaluate the stress components that drive the damage modes. Significance. Microstructure is confirmed to be a controlling factor in determining the nature and degree of strength-impairing damage accumulation in dental ceramics. The Hertzian test provides a means of characterizing such damage in the context of clinical function. (C) 1998 Academy of Dental Materials. Published by Elsevier Science Ltd.
引用
收藏
页码:80 / 89
页数:10
相关论文
共 39 条
[1]  
[Anonymous], HERTZS MISCELLANEOUS
[2]  
ANUSAVICE KJ, 1989, QUALITY EVALUATION D, P15
[3]   CYCLIC FATIGUE OF A MICA-CONTAINING GLASS-CERAMIC AT HERTZIAN CONTACTS [J].
CAI, HD ;
KALCEFF, MAS ;
HOOKS, BM ;
LAWN, BR ;
CHYUNG, K .
JOURNAL OF MATERIALS RESEARCH, 1994, 9 (10) :2654-2661
[4]   DEFORMATION AND FRACTURE OF MICA-CONTAINING GLASS-CERAMICS IN HERTZIAN CONTACTS [J].
CAI, HD ;
KALCEFF, MAS ;
LAWN, BR .
JOURNAL OF MATERIALS RESEARCH, 1994, 9 (03) :762-770
[5]  
CHYUNG CK, 1974, P 10 INT GLASS C, V14, P33
[6]  
CHYUNG CK, 1972, ELECT MICROSCOPY STR, P1167
[7]  
CRAIG RG, 1997, RESTORATIVE DENT MAT, pCH4
[8]   THE DETERMINATION OF STATIC AND DYNAMIC YIELD STRESSES USING A STEEL BALL [J].
DAVIES, RM .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1949, 197 (1050) :416-432
[9]   DEVELOPMENT OF AN ARTIFICIAL ORAL ENVIRONMENT FOR THE TESTING OF DENTAL RESTORATIVES - BI-AXIAL FORCE AND MOVEMENT CONTROL [J].
DELONG, R ;
DOUGLAS, WH .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (01) :32-36
[10]  
DENRY IKL, 1996, J DENT RES, V75, P125