Organophosphate and phthalate esters in indoor air: a comparison between multi-storey buildings with high and low prevalence of sick building symptoms

被引:54
作者
Bergh, Caroline [1 ]
Aberg, K. Magnus [1 ]
Svartengren, Magnus [2 ]
Emenius, Gunnel [2 ]
Ostman, Conny [1 ]
机构
[1] Stockholm Univ, Dept Analyt Chem, SE-10691 Stockholm, Sweden
[2] Karolinska Inst, Dept Publ Hlth Sci, Div Occupat & Environm Med, SE-17176 Stockholm, Sweden
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2011年 / 13卷 / 07期
关键词
SEMIVOLATILE ORGANIC-COMPOUNDS; ENDOCRINE-DISRUPTING COMPOUNDS; FLAME RETARDANTS; GAS-CHROMATOGRAPHY; VENTILATION RATES; EXPOSURE; DUST; ENVIRONMENTS; PLASTICIZERS; ASSOCIATION;
D O I
10.1039/c1em10152h
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
An extensive study has been conducted on the prevalence of organophosphorous flame retardants/plasticizers and phthalate ester plasticizers in indoor air. The targeted substances were measured in 45 multi-storey apartment buildings in Stockholm, Sweden. The apartment buildings were classified as high or low risk with regard to the reporting of sick building symptoms (SBS) within the project Healthy Sustainable Houses in Stockholm (3H). Air samples were taken from two to four apartments per building (in total 169 apartments) to facilitate comparison within and between buildings. Association with building characteristics has been examined as well as association with specific sources by combining chemical analysis and exploratory uni- and multivariate data analysis. The study contributes to the overall perspective of levels of organophosphate and phthalate ester in indoor air enabling comparison with other studies. The results indicated little or no difference in the concentrations of the target substances between the two risk classifications of the buildings. The differences between the apartments sampled within (intra) buildings were greater than the differences between (inter) buildings. The concentrations measured in air ranged up to 1200 ng m(-3) for organophosphate esters and up to 11 000 ng m(-3) for phthalate esters. Results in terms of sources were discerned e. g. PVC flooring is a major source of benzylbutyl phthalate in indoor air.
引用
收藏
页码:2001 / 2009
页数:9
相关论文
共 66 条
[1]
Emission of phthalates from PVC and other materials [J].
Afshari, A ;
Gunnarsen, L ;
Clausen, PA ;
Hansen, V .
INDOOR AIR, 2004, 14 (02) :120-128
[2]
[Anonymous], 1991, USERS GUIDE PRINCIPA
[3]
Organophosphate and phthalate esters in air and settled dust - a multi-location indoor study [J].
Bergh, C. ;
Torgrip, R. ;
Emenius, G. ;
Ostman, C. .
INDOOR AIR, 2011, 21 (01) :67-76
[4]
Simultaneous selective detection of organophosphate and phthalate esters using gas chromatography with positive ion chemical ionization tandem mass spectrometry and its application to indoor air and dust [J].
Bergh, Caroline ;
Torgrip, Ralf ;
Ostman, Conny .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (19) :2859-2867
[5]
Phthalate exposure and asthma in children [J].
Bornehag, C. G. ;
Nanberg, E. .
INTERNATIONAL JOURNAL OF ANDROLOGY, 2010, 33 (02) :333-345
[6]
Phthalates in indoor dust and their association with building characteristics [J].
Bornehag, CG ;
Lundgren, B ;
Weschler, CJ ;
Sigsgaard, T ;
Hagerhed-Engman, L ;
Sundell, J .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2005, 113 (10) :1399-1404
[7]
Association between ventilation rates in 390 Swedish homes and allergic symptoms in children [J].
Bornehag, CG ;
Sundell, J ;
Hägerhed-Engman, L ;
Sigsgaard, T .
INDOOR AIR, 2005, 15 (04) :275-280
[8]
Sick building syndrome [J].
Burge, PS .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2004, 61 (02) :185-190
[9]
ECHA, 2008, ECHA200802SR5ECA227
[10]
*ECPI, 2010, SECT GROUP CEF