Microstructured optical fiber interferometric breathing sensor

被引:52
作者
Favero, Fernando C. [1 ,2 ]
Villatoro, Joel [1 ]
Pruneri, Valerio [1 ,3 ]
机构
[1] ICFO Inst Photon Sci, Barcelona 08860, Spain
[2] Pontifical Catholic Univ Rio de Janeiro, BR-22453900 Rio De Janeiro, Brazil
[3] ICREA Inst Catalana Recerca & Estudis Avancats, Barcelona 08010, Spain
关键词
fiber optic sensors; interferometers; interferometry; optical breathing sensors; HUMIDITY; CARE;
D O I
10.1117/1.JBO.17.3.037006
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
In this paper a simple photonic crystal fiber (PCF) interferometric breathing sensor is introduced. The interferometer consists of a section of PCF fusion spliced at the distal end of a standard telecommunications optical fiber. Two collapsed regions in the PCF caused by the splicing process allow the excitation and recombination of a core and a cladding PCF mode. As a result, the reflection spectrum of the device exhibits a sinusoidal interference pattern that instantly shifts when water molecules, present in exhaled air, are adsorbed on or desorbed from the PCF surface. The device can be used to monitor a person's breathing whatever the respiration rate. The device here proposed could be particularly important in applications where electronic sensors fail or are not recommended. It may also be useful in the evaluation of a person's health and even in the diagnosis and study of the progression of serious illnesses such as sleep apnea syndrome. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.3.037006]
引用
收藏
页数:5
相关论文
共 20 条
[1]
A monitoring of breathing using a hetero-core optical fiber sensor [J].
Akita, S. ;
Seki, A. ;
Watanabe, K. .
SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2011, 2011, 7981
[2]
Respiration Rate Monitoring Methods: A Review [J].
AL-Khalidi, F. Q. ;
Saatchi, R. ;
Burke, D. ;
Elphick, H. ;
Tan, S. .
PEDIATRIC PULMONOLOGY, 2011, 46 (06) :523-529
[3]
Optical fiber humidity sensor using a nano Fabry-Perot cavity formed by the ionic self-assembly method [J].
Arregui, FJ ;
Liu, YJ ;
Matias, IR ;
Claus, RO .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 59 (01) :54-59
[4]
Fiber optic sensor for the measurement of respiratory chest circumference changes [J].
Babchenko, A ;
Khanokh, B ;
Shomer, Y ;
Nitzan, M .
JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (02) :224-229
[5]
Photonic crystal fiber sensor array based on modes overlapping [J].
Cardenas-Sevilla, Guillermo A. ;
Finazzi, Vittoria ;
Villatoro, Joel ;
Pruneri, Valerio .
OPTICS EXPRESS, 2011, 19 (08) :7596-7602
[6]
Breathing detection:: Towards a miniaturized, wearable, battery-operated monitoring system [J].
Corbishley, Phil ;
Rodriguez-Villegas, Esther .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (01) :196-204
[7]
Critical review of non-invasive respiratory monitoring in medical care [J].
Folke, M ;
Cernerud, L ;
Ekström, M ;
Hök, B .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (04) :377-383
[8]
Optical fiber sensors embedded into medical textiles for healthcare monitoring [J].
Grillet, Augustin ;
Kinet, Damien ;
Witt, Jens ;
Schukar, Marcus ;
Krebber, Katerina ;
Pirotte, Fabrice ;
Depre, Annick .
IEEE SENSORS JOURNAL, 2008, 8 (7-8) :1215-1222
[9]
Nanostructured optical fibre sensors for breathing airflow monitoring [J].
Kang, Y. ;
Ruan, H. ;
Wang, Y. ;
Arregui, F. J. ;
Matias, I. R. ;
Claus, R. O. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (05) :1207-1210
[10]
Humidity sensor based on photonic crystal fibre interferometer [J].
Mathew, J. ;
Semenova, Y. ;
Rajan, G. ;
Farrell, G. .
ELECTRONICS LETTERS, 2010, 46 (19) :1341-1343