RCD snubber revisited

被引:62
作者
Finney, SJ [1 ]
Williams, BW [1 ]
Green, TC [1 ]
机构
[1] UNIV LONDON IMPERIAL COLL SCI TECHNOL & MED,DEPT ELECT & ELECTR ENGN,LONDON SW7 2BT,ENGLAND
关键词
D O I
10.1109/28.485827
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The use of the polarized RCD turn-off snubber configuration across switching devices is popular because of its simplicity and use of only passive components, This configuration is limited by the fact that all capacitor-stored energy is dissipated in the discharge resistor. In this paper it is shown that with the addition of a ferrite transformer to the standard RCD arrangement, in excess of 70% of the energy stored on the snubber capacitor may be passively recovered into the dc supply, Performance of this passive recovery snubber is supported by theoretical, simulated and practical results.
引用
收藏
页码:155 / 160
页数:6
相关论文
共 6 条
  • [1] BOEHRINGER A, 1979, ELEKTROTECH Z, V100, P664
  • [2] A NONDISSIPATIVE SNUBBER CIRCUIT FOR HIGH-POWER GTO INVERTERS
    HOLTZ, J
    SALAMA, S
    WERNER, KH
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1989, 25 (04) : 620 - 626
  • [3] Lauritzen P. O., 1983, PESC'83 Record. 14th Annual IEEE Power Electronics Specialists Conference, P345
  • [4] McMurray W., 1985, PESC '85 Record. 16th Annual IEEE Power Electronics Specialists Conference (Cat. No. 85CH2117-0), P20
  • [5] SNEYERS B, 1987, P 2 EUR C POW EL APP, P31
  • [6] WILLIAMS BW, 1984, IEE P B, V131, P264