Dosimetric comparison of the specific anthropomorphic mannequin (SAM) to 14 anatomical head models using a novel definition for the mobile phone positioning

被引:58
作者
Kainz, W
Christ, A
Kellom, T
Seidman, S
Nikoloski, N
Beard, B
Kuster, N
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Rockville, MD 20852 USA
[2] ITIS, Fdn Res Informat Technol Soc, CH-8004 Zurich, Switzerland
关键词
D O I
10.1088/0031-9155/50/14/016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents new definitions for obtaining reproducible results in numerical phone dosimetry. Numerous numerical dosimetric studies have been published about the exposure of mobile phone users which concluded with conflicting results. However, many of these studies lack reproducibility due to shortcomings in the description of the phone positioning. The new approach was tested by two groups applying two different numerical program packages to compare the specific anthropomorphic mannequin (SAM) to 14 anatomically correct head models. A novel definition for the positioning of mobile phones next to anatomically correct head models is given along with other essential parameters to be reported. The definition is solely based on anatomical characteristics of the head. A simple up-to-date phone model was used to determine the peak spatial specific absorption rate (SAR) of mobile phones in SAM and in the anatomically correct head models. The results were validated by measurements. The study clearly shows that SAM gives a conservative estimate of the exposure in anatomically correct head models for head only tissue. Depending on frequency, phone position and head size the numerically calculated 10 g averaged SAR in the pinna can be up to 2.1 times greater than the peak spatial SAR in SAM. Measurements in small structures, such as the pinna, will significantly increase the uncertainty; therefore SAM was designed for SAR assessment in the head only. Whether SAM will provide a conservative value for the pinna depends on the pinna SAR limit of the safety standard considered.
引用
收藏
页码:3423 / 3445
页数:23
相关论文
共 29 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]   Comparisons of peak SAR levels in concentric sphere head models of children and adults for irradiation by a dipole at 900 MHz [J].
Anderson, V .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (20) :3263-3275
[3]  
[Anonymous], 2002, C9532002 IEEE
[4]   Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models [J].
Beard, Brian B. ;
Kainz, Wolfgang .
BIOMEDICAL ENGINEERING ONLINE, 2004, 3 (1)
[5]   Evaluation of the SAR distribution in the human head for cellular phones used in a partially closed environment [J].
Bernardi, P ;
Cavagnaro, M ;
Pisa, S .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1996, 38 (03) :357-366
[6]   Suitability of FDTD-based TCAD tools for RF design of mobile phones [J].
Chavannes, N ;
Tay, R ;
Nikoloski, N ;
Kuster, N .
IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2003, 45 (06) :52-66
[7]   A numerical and experimental comparison of human head phantoms for compliance testing of mobile telephone equipment [J].
Christ, A ;
Chavannes, N ;
Nikoloski, N ;
Gerber, HU ;
Pokovic, K ;
Kuster, N .
BIOELECTROMAGNETICS, 2005, 26 (02) :125-137
[8]   SAR CALCULATIONS IN AN ANATOMICALLY REALISTIC MODEL OF THE HEAD FOR MOBILE COMMUNICATION TRANSCEIVERS AT 900-MHZ AND 1.8-GHZ [J].
DIMBYLOW, PJ ;
MANN, SM .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10) :1537-1553
[9]  
*EUR COMM EL STAND, 2001, 50361 EN EUR COMM EL
[10]   Electromagnetic absorption in the human head and neck for mobile telephones at 835 and 1900 MHz [J].
Gandhi, OP ;
Lazzi, G ;
Furse, CM .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) :1884-1897