Randomized comparison of sirolimus-eluting stent versus standard stent for percutaneous coronary revascularization in diabetic patients -: The diabetes and sirolimus-eluting stent (DIABETES) trial

被引:284
作者
Sabaté, M
Jiménez-Quevedo, P
Angiolillo, DJ
Gómez-Hospital, JA
Alfonso, F
Hernández-Antolín, R
Goicolea, J
Bañuelos, C
Escaned, J
Moreno, RL
Fernández, C
Fernández-Avilés, F
Macaya, C
机构
[1] Sao Carlos Univ Hosp, Serv Cardiol Intervencion, Madrid 28040, Spain
[2] Hosp Clin San Carlos, Res Unit, Madrid, Spain
[3] Princeps Espanya Univ Hosp, Barcelona, Spain
[4] Meixoeiro Univ Hosp, Vigo, Spain
[5] Clin Univ Hosp, Valladolid, Spain
关键词
diabetes mellitus; restenosis; stents; trials;
D O I
10.1161/CIRCULATIONAHA.105.562421
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Outcomes after percutaneous coronary interventions in diabetic patients are shadowed by the increased rate of recurrence compared with nondiabetic patients. Methods and Results-We conducted a multicenter, randomized trial to demonstrate the efficacy of sirolimus-eluting stents compared with standard stents to prevent restenosis in diabetic patients with de novo lesions in native coronary arteries. The primary end point of the trial was in-segment late lumen loss as assessed by quantitative coronary angiography at 9-month follow-up. The trial was stratified by diabetes treatment status. One hundred sixty patients were randomized to sirolimus-eluting stents ( 80 patients; 111 lesions) or standard stent implantation ( 80 patients; 110 lesions). On average, reference diameter was 2.34 +/- 0.6 mm, lesion length was 15.0 +/- 8 mm, and 13.1% of lesions were chronic total occlusions. In-segment late lumen loss was reduced from 0.47 +/- 0.5 mm for standard stents to 0.06 +/- 0.4 mm for sirolimus stents ( P < 0.001). Target-lesion revascularization and major adverse cardiac event rates were significantly lower in the sirolimus group (31.3% versus 7.3% and 36.3% versus 11.3%, respectively; both P < 0.001). Non-insulinand insulin-requiring patients demonstrated similar reductions in angiographic and clinical parameters of restenosis after sirolimus-eluting stent implantation. During the 9-month follow-up, stent thrombosis occurred in 2 patients after standard stent implantation. Conversely, this phenomenon was not seen in the sirolimus stent group. Conclusions-This randomized trial demonstrated that sirolimus stent implantation is safe and efficacious in reducing both angiographic and clinical parameters of restenosis compared with standard stents in diabetic patients with de novo coronary stenoses.
引用
收藏
页码:2175 / 2183
页数:9
相关论文
共 28 条
[1]   Sirolimus-eluting stents inhibit neointimal hyperplasia in diabetic patients - Insights from the RAVEL Trial [J].
Abizaid, A ;
Costa, MA ;
Blanchard, D ;
Albertal, M ;
Eltchaninoff, H ;
Guagliumi, G ;
Geert-Jan, L ;
Abizaid, AS ;
Sousa, AGMR ;
Wuelfert, E ;
Wietze, L ;
Sousa, JE ;
Serruys, PW ;
Morice, MC .
EUROPEAN HEART JOURNAL, 2004, 25 (02) :107-112
[2]  
Alberti KGMM, 1998, DIABETIC MED, V15, P539, DOI 10.1002/(SICI)1096-9136(199807)15:7<539::AID-DIA668>3.0.CO
[3]  
2-S
[4]   Candy wrapper effect after drug-eluting stent implantation:: Deja vu or stumbling over the same stone again? [J].
Angiolillo, DJ ;
Sabatá, M ;
Alfonso, F ;
Macaya, C .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (03) :387-391
[5]  
[Anonymous], 1989, DIABETES CARE, V12, P573
[6]   Does hyperglycemia really cause coronary heart disease? [J].
BarrettConnor, E .
DIABETES CARE, 1997, 20 (10) :1620-1623
[7]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[8]   Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement [J].
Elezi, S ;
Kastrati, A ;
Pache, J ;
Wehinger, A ;
Hadamitzky, M ;
Dirschinger, J ;
Neumann, FJ ;
Schömig, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1866-1873
[9]  
Geiss LS., 1995, Diabetes in America, V2nd, P233
[10]   Outcomes with the polymer-based paclitaxel-eluting TAXUS stent in patients with diabetes mellitus - The TAXUS-IV trial [J].
Hermiller, JB ;
Raizner, A ;
Cannon, L ;
Gurbel, PA ;
Kutcher, MA ;
Wong, SC ;
Russell, ME ;
Ellis, SG ;
Mehran, R ;
Stone, GW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (08) :1172-1179