Protein quantification by isotope dilution mass spectrometry of proteolytic fragments:: Cleavage rate and accuracy

被引:106
作者
Arsene, Cristian G. [1 ]
Ohlendorf, Ruediger [1 ]
Burkitt, William [2 ]
Pritchard, Caroline [2 ]
Henrion, Andre [1 ]
O'Connor, Gavin [2 ]
Bunk, David M. [3 ]
Guettler, Bernd [1 ,2 ]
机构
[1] Phys Tech Bundesanstalt, Dept Metrol Chem, D-38116 Braunschweig, Germany
[2] Lab Govt Chemist, Dept Mass Spectrometry, Teddington TW11 0LY, Middx, England
[3] Natl Inst Stand & Technol, Div Analyt Chem, Gaithersburg, MD 20899 USA
关键词
D O I
10.1021/ac7024738
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The practice of quantifying proteins by peptide fragments from enzymatic proteolysis (digestion) was assessed regarding accuracy, reliability, and uncertainty of the results attainable. Purified recombinant growth hormone (rhGH, 22 kDa isoform) was used as a model analyte. Two tryptic peptides from hGH, T6 and T12, were chosen to determine the amount of the protein in the original sample. Reference solutions of T6 and T12 (isotopically labeled forms), value assigned by quantitative amino acid analysis (AAA) after complete hydrolysis, were used as internal standards. The accuracy of protein quantification by fragments T6 and T12 was evaluated by comparison of peptide results to those obtained for the same rhGH sample by AAA. The rate of cleavage (and thus the experimental protocol used) turned out to be crucial to the quality of results in protein quantification using enzymatic fragments. Applying a protocol customarily found in (qualitative) bottom-up proteomics gave results significantly higher than the target value from AAA (+ 11 % with T6 and +6% with T12). In contrast, using a modified protocol optimized for fast and complete hydrolysis, results were unbiased within the limits of uncertainty, while the time needed for completion of proteolysis was considerably reduced (30 min as compared to 10801200 min). The method assessed highlighted three important criteria deemed necessary for successful protein quantification using proteolysis-based mass spectrometry methods. These are the following: the requirement for both the selected peptides and labeled internal standard to be stable throughout digestion; the correct purity assignment to the selected peptide standards; the proof of equimolar release of the selected peptides. The combined (overall) uncertainty for protein quantification was established by combination of estimates obtained for individual components and found to be U = 4% for this example. This uncertainty is of the same order as that typically attainable in quantification of "small" organic molecules using liquid chromatography/isotope dilution mass spectrometry.
引用
收藏
页码:4154 / 4160
页数:7
相关论文
共 28 条
[1]   Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins [J].
Anderson, L ;
Hunter, CL .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (04) :573-588
[2]  
Anderson RL, 1952, STAT THEORY RES
[3]   Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-MS/MS using protein cleavage and isotope dilution mass spectrometry [J].
Barnidge, DR ;
Goodmanson, MK ;
Klee, GG ;
Muddiman, DC .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (03) :644-652
[4]   Absolute quantification of the G protein-coupled receptor rhodopsin by LC/MS/MS using proteolysis product peptides and synthetic peptide standards [J].
Barnidge, DR ;
Dratz, EA ;
Martin, T ;
Bonilla, LE ;
Moran, LB ;
Lindall, A .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :445-451
[5]  
BARR JR, 1996, CLIN CHEM, V42, P676
[6]   Isotope-labeled protein standards [J].
Brun, Virginie ;
Dupuis, Alain ;
Adrait, Annie ;
Marcellin, Marlene ;
Thomas, Damien ;
Court, Magali ;
Vandenesch, Francois ;
Garin, Jerome .
MOLECULAR & CELLULAR PROTEOMICS, 2007, 6 (12) :2139-2149
[7]   Electrospray ionization mass spectrometry for the quantitation of albumin in human serum [J].
Bunk, DM ;
Welch, MJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (12) :1247-1254
[8]   Toward Systeme International d'Unite-traceable protein quantification: From amino acids to proteins [J].
Burkitt, William I. ;
Pritchard, Caroline ;
Arsene, Cristian ;
Henrion, Andre ;
Bunk, David ;
O'Connor, Gavin .
ANALYTICAL BIOCHEMISTRY, 2008, 376 (02) :242-251
[9]   APPLICATIONS OF ISOTOPE-DILUTION MASS-SPECTROMETRY IN CLINICAL-CHEMISTRY, PHARMACOKINETICS, AND TOXICOLOGY [J].
DELEENHEER, AP ;
THIENPONT, LM .
MASS SPECTROMETRY REVIEWS, 1992, 11 (04) :249-307
[10]   Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS [J].
Gerber, SA ;
Rush, J ;
Stemman, O ;
Kirschner, MW ;
Gygi, SP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (12) :6940-6945