Multicenter evaluation of the NucliSens EasyQ HIV-1 v1.1 assay for the quantitative detection of HIV-1 RNA in plasma

被引:35
作者
de Mendoza, C
Koppelman, M
Montès, B
Ferre, V
Soriano, V
Cuypers, H
Segondy, M
Oosterlaken, T
机构
[1] Hosp Carlos III, Dept Infect Dis, Madrid 28029, Spain
[2] CLB, Sanquin Div, Amsterdam, Netherlands
[3] CHU St Eloi, Montpellier, France
[4] CHU Nantes, Hotel Dieu, F-44035 Nantes, France
[5] BioMerieux, Boxtel, Netherlands
关键词
HIV-RNA; viral load; real-time PCR; non-B subtypes;
D O I
10.1016/j.jviromet.2005.03.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The Nuclisens EasyQ HIV-1 v1.1 assay (Biomerieux) is a real-time detection method combined with NASBA technology designed to measure plasma HIV-RNA. Its performance was assessed in 1008 clinical specimens collected from individuals infected with clade B (774) and non-B (234) HIV-1 variants at four European laboratories. The results were compared with those obtained using three other commercial viral load assays: Cobas Amplicor Monitor HIV-1 v 1.5 (Roche), Versant HIV-1 RNA assay (Bayer) and Nuclisens HIV-1 QT (Biomerieux). Overall, the linearity, specificity and reproducibility of the EasyQ assay was comparable with that from the other tests. The correlation coefficient (R) between methodologies was 0.85 for Amplicor; 0.87 for Versant; and 0.91 for Nuclisens. The specificity of the assay was 99.4%. Of note, Versant missed 17% of specimens with non-B subtypes which could be detected by EasyQ, while Amplicor provided similar results than EasyQ. HIV-1 group 0 specimens were only detected by the EasyQ assay. In conclusion, the performance of the EasyQ assay seems to be similar to that of other HIV-1 viral load tests currently on the market, but it is more sensitive than Versant for HIV-1 non-B subtypes and shows a wider dynamic range than Amplicor. Moreover, as it incorporates the advantage of real-time detection procedures, it facilitates high throughput and short turnaround time. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 27 条
[1]   Subtype-specific problems with quantification of plasma HIV-1 RNA [J].
Alaeus, A ;
Lidman, K ;
Sonnerborg, A ;
Albert, J .
AIDS, 1997, 11 (07) :859-865
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Multisite comparison of reproducibility and recovery from the standard and ultrasensitive Roche AMPLICOR HIV-1 MONITOR assays [J].
Brambilla, DJ ;
Granger, S ;
Jennings, C ;
Bremer, JW .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (03) :1121-1123
[4]   Immune reconstitution in the first year of potent antiretroviral therapy and its relationship to virologic response [J].
Connick, E ;
Lederman, MM ;
Kotzin, BL ;
Spritzler, J ;
Kuritzkes, DR ;
St Clair, M ;
Sevin, AD ;
Fox, L ;
Chiozzi, MH ;
Leonard, JM ;
Rousseau, F ;
Roe, JD ;
Martinez, A ;
Kessler, H ;
Landay, A .
JOURNAL OF INFECTIOUS DISEASES, 2000, 181 (01) :358-363
[5]   False positives for HIV using commercial viral load quantification assay [J].
de Mendoza, C ;
Holguín, A ;
Soriano, V .
AIDS, 1998, 12 (15) :2076-2077
[6]   Comparison of NucliSens and Roche monitor assays for quantitation of levels of human immunodeficiency virus type 1 RNA in plasma [J].
Dyer, JR ;
Pilcher, CD ;
Shepard, R ;
Schock, J ;
Eron, JJ ;
Fiscus, SA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (02) :447-449
[7]   Performance characteristics of the QUANTIPLEX HIV-1 RNA 3.0 assay for detection and quantitation of human immunodeficiency virus type 1 RNA in plasma [J].
Erice, A ;
Brambilla, D ;
Bremer, J ;
Jackson, JB ;
Kokka, R ;
Yen-Lieberman, B ;
Coombs, RW .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (08) :2837-2845
[8]   Strategies for long-term success in the treatment of HIV infection [J].
Gallant, JE .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (10) :1329-1334
[9]   Multicenter evaluation of the performance characteristics of the NucliSens HIV-1 QT assay used for quantitation of human immunodeficiency virus type 1 RNA [J].
Ginocchio, CC ;
Kemper, M ;
Stellrecht, KA ;
Witt, DJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (01) :164-173
[10]   Drug-selected resistance mutations and non-B subtypes in antiretroviral-naive adults with established human immunodeficiency virus infection [J].
Hanna, GJ ;
Balaguera, HU ;
Freedberg, KA ;
Werner, BG ;
Craven, KAS ;
Craven, DE ;
D'Aquila, RT .
JOURNAL OF INFECTIOUS DISEASES, 2003, 188 (07) :986-991