A method to increase the sensitive range of pressure sensitive film

被引:15
作者
Atkinson, PJ
Newberry, WN
Atkinson, TS
Haut, RC
机构
[1] Michigan State Univ, Coll Osteopath Med, Orthopaed Biomech Labs, E Lansing, MI 48824 USA
[2] Michigan State Univ, Coll Engn, Dept Mech & Mat Sci, E Lansing, MI 48824 USA
关键词
pressure sensitive film; contact pressure; contact area; diarthrodial joints; impact;
D O I
10.1016/S0021-9290(98)00090-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Pressure-sensitive film is frequently used in biomechanics to document intra- and extra-articular contact pressures. This often involves the contact of two surfaces of varying curvature producing non-uniform pressure distributions. The purpose of this study was to determine the feasibility of using multiple films in such experiments to yield accurate pressure and contact area data. A composite arrangement of film was dynamically loaded using cylindrical indenters of five radii. An analytical model of each indentation was constructed to provide a standard for error analysis. The study showed that several ranges of pressure sensitive film can be used simultaneously to accurately transduce contact pressures arising from loading scenarios that produce contact pressure gradients and contact pressures that involve suprathreshold loading of a given film range. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:855 / 859
页数:5
相关论文
共 13 条
[1]   Subfracture insult to the human cadaver patellofemoral joint produces occult injury [J].
Atkinson, P ;
Haut, RC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (06) :936-944
[2]  
ATKINSON PJ, 1995, 39 STAPP CAR CRASH C, P281
[3]  
ATKINSON PJ, 1997, P 44 ANN M ORTH RES, P656
[4]   THE CONTACT AREA AND PRESSURE DISTRIBUTION PATTERN OF THE KNEE - A STUDY OF NORMAL AND OSTEOARTHROTIC KNEE JOINTS [J].
FUKUBAYASHI, T ;
KUROSAWA, H .
ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (06) :871-879
[5]   CONTACT STRESS GRADIENT DETECTION LIMITS OF PRESSENSOR FILM [J].
HALE, JE ;
BROWN, TD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (03) :352-357
[6]   CONTACT PRESSURES IN THE PATELLOFEMORAL JOINT DURING IMPACT LOADING ON THE HUMAN FLEXED KNEE [J].
HAUT, RC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (02) :272-280
[7]   Mechanical responses of the rabbit patello-femoral joint to blunt impact [J].
Haut, RC ;
Ide, TM ;
DeCamp, CE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (04) :402-408
[8]   AXISYMMETRIC FINITE-ELEMENT ANALYSIS OF LATERAL TIBIAL PLATEAU [J].
HAYES, WC ;
SWENSON, LW ;
SCHURMAN, DJ .
JOURNAL OF BIOMECHANICS, 1978, 11 (1-2) :21-33
[9]   An analytical model to study blunt impact response of the rabbit P-F joint [J].
Li, XW ;
Haut, RC ;
Altiero, NJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (04) :485-491
[10]   Subfracture insult to a knee joint causes alterations in the bone and in the functional stiffness of overlying cartilage [J].
Newberry, WN ;
Zukosky, DK ;
Haut, RC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (03) :450-455