Liquid chromatography microspray mass spectrometry for bacterial investigations

被引:3
作者
Krishnamurthy, T [1 ]
Davis, MT
Stahl, DC
Lee, TD
机构
[1] USA, R&T Directorate, Edgewood RD&E Ctr, Aberdeen Proving Ground, MD 21010 USA
[2] City Hope Natl Med Ctr, Beckman Res Inst, Duarte, CA 91010 USA
关键词
D O I
10.1002/(SICI)1097-0231(19990115)13:1<39::AID-RCM445>3.0.CO;2-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cellular proteins (biomarkers) specific to any individual microorganism, determined by the direct mass spectral analysis of the corresponding intact cellular suspension, can be applied for the rapid and specific identification of the organisms present in unknown samples. The components of the bacterial suspensions, after a rapid separation over a Cls reversed-phase microcapillary column, were directly subjected to on-line electrospray ionization followed by analysis using an ion trap tandem mass spectrometer, This approach is equally effective for gram-positive as well as gram-negative bacteria but has a distinct advantage over our earlier reported method involving matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). During electrospray ionitation mass spectrometry (ESI-MS), liquid samples can be directly analyzed and there is the potential for developing tandem mass spectral methods for more specific identification of the individual organisms present in crude bacterial mixtures. The total analysis time leading to unambiguous bacterial identification in samples was less than 10 minutes and the results were quite reproducible. Miniaturization of the instrumentation along with total automation of this simple process could have immense impact on field operations. Routine, rapid, cost-effective field monitoring of environmental samples, agricultural products, samples from food processing, industrial sites and health institutions for suspected bacterial contamination could be a reality in the near future. Potential utility in biological, medical, bioprocessing, pharmaceutical, and other industrial research is also enormous. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:39 / 49
页数:11
相关论文
共 46 条
[1]  
Arnold RJ, 1998, RAPID COMMUN MASS SP, V12, P630, DOI 10.1002/(SICI)1097-0231(19980529)12:10<630::AID-RCM206>3.3.CO
[2]  
2-S
[3]   ELECTROSPRAY TANDEM MASS-SPECTROMETRY FOR ANALYSIS OF NATIVE MURAMIC ACID IN WHOLE BACTERIAL-CELL HYDROLYSATES [J].
BLACK, GE ;
FOX, A ;
FOX, K ;
SNYDER, AP ;
SMITH, PBW .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4171-4176
[4]  
Chong BE, 1997, RAPID COMMUN MASS SP, V11, P1900, DOI 10.1002/(SICI)1097-0231(199711)11:17<1900::AID-RCM95>3.0.CO
[5]  
2-K
[6]   The rapid identification of intact microorganisms using mass spectrometry [J].
Claydon, MA ;
Davey, SN ;
EdwardsJones, V ;
Gordon, DB .
NATURE BIOTECHNOLOGY, 1996, 14 (11) :1584-1586
[7]   DIRECT DETERMINATION OF PHOSPHOLIPID STRUCTURES IN MICROORGANISMS BY FAST-ATOM-BOMBARDMENT TRIPLE QUADRUPOLE MASS-SPECTROMETRY [J].
COLE, MJ ;
ENKE, CG .
ANALYTICAL CHEMISTRY, 1991, 63 (10) :1032-1038
[8]   Rapid protein identification using a microscale electrospray LC/MS system on an ion trap mass spectrometer [J].
Davis, MT ;
Lee, TD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (03) :194-201
[9]  
DAVIS MT, 1998, P 46 ASMS C MASS SPE
[10]   ANALYSIS OF POLYMERASE CHAIN REACTION-AMPLIFIED DNA PRODUCTS BY MASS-SPECTROMETRY USING MATRIX-ASSISTED LASER-DESORPTION AND ELECTROSPRAY - CURRENT STATUS [J].
DOKTYCZ, MJ ;
HURST, GB ;
HABIBIGOUDARZI, S ;
MCLUCKEY, SA ;
TANG, K ;
CHEN, CH ;
UZIEL, M ;
JACOBSON, KB ;
WOYCHIK, RP ;
BUCHANAN, MV .
ANALYTICAL BIOCHEMISTRY, 1995, 230 (02) :205-214