Clinical outcome after undisplaced femoral neck fractures

被引:155
作者
Gjertsen, Jan-Erik [1 ]
Fevang, Jonas M. [1 ]
Matre, Kjell [1 ]
Vinje, Tarjei [1 ]
Engesaeter, Lars B. [1 ,2 ]
机构
[1] Haukeland Hosp, Dept Orthopaed Surg, N-5021 Bergen, Norway
[2] Univ Bergen, Dept Surg Sci, Bergen, Norway
关键词
INTRACAPSULAR HIP-FRACTURES; INTERNAL-FIXATION; DISPLACED FRACTURES; ELDERLY-PATIENTS; CONTROLLED-TRIAL; HEMIARTHROPLASTY; ARTHROPLASTY; REPLACEMENT; REGISTER; UTILITY;
D O I
10.3109/17453674.2011.588857
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Methods Data on 4,468 patients with undisplaced femoral neck fractures who were operated with screw osteosynthesis were compared to those from 10,289 patients with displaced femoral neck fractures treated with screw osteosynthesis (n == 3,389) or bipolar hemiarthroplasty (n == 6,900). The evaluation was based on number of reoperations and patient assessment at 4 and 12 months of follow-up. Results The 1-year implant survival was 89% after screw fixation for undisplaced fractures, 79% after screw fixation for displaced fractures, and 97% after hemiarthroplasty for displaced fractures. Patients with displaced fractures who were operated with internal fixation had a higher risk of reoperation (RR == 1.9, CI: 1.7--2.2), reported more pain, were less satisfied, and had lower quality of life than patients with undisplaced fractures treated with internal fixation (p < 0.05). Patients with displaced fractures who were operated with hemiarthroplasty had a lower risk of reoperation than patients with undisplaced fractures who were operated with internal fixation (RR == 0.32, CI: 0.27--0.38). Furthermore, they had the lowest degree of pain, were most satisfied, and reported the highest quality of life. Interpretation The differences in clinical outcome found were less than what is considered to be of clinical importance. The results support the use of screw osteosynthesis for undisplaced femoral neck fractures in elderly patients, although even better results were obtained in the hemiarthroplasty group in patients with displaced fractures.
引用
收藏
页码:268 / 274
页数:7
相关论文
共 23 条
[1]
Total hip arthroplasty and hemiarthroplasty in mobile, independent patients with a displaced intracapsular fracture of the femoral neck - A randomized, controlled trial [J].
Baker, R. P. ;
Squires, B. ;
Gargan, M. F. ;
Bannister, G. C. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) :2583-2589
[2]
Outcome of undisplaced and moderately displaced femoral neck fractures -: A prospective study of 466 patients treated by internal fixation [J].
Bjorgul, Kristian ;
Reikeras, Olav .
ACTA ORTHOPAEDICA, 2007, 78 (04) :498-504
[3]
Blomfeldt R, 2005, J BONE JOINT SURG BR, V87B, P523, DOI 10.1302/0301-620X.87B4
[4]
EuroQol: The current state of play [J].
Brooks, R .
HEALTH POLICY, 1996, 37 (01) :53-72
[5]
Undisplaced intracapsular hip fractures - Results of internal fixation in 375 patients [J].
Conn, KS ;
Parker, MJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (421) :249-254
[6]
Ehrich EW, 2000, J RHEUMATOL, V27, P2635
[7]
Engesaeter L, 2010, NORWEGIAN ARTHROPLAS
[8]
Registration completeness in the Norwegian Arthroplasty Register [J].
Espehaug, B ;
Furnes, O ;
Havelin, LI ;
Engesæter, LB ;
Vollset, SE ;
Kindseth, A .
ACTA ORTHOPAEDICA, 2006, 77 (01) :49-56
[9]
Hemiarthroplasty or internal fixation for intracapsular displaced femoral neck fractures: randomised controlled trial [J].
Frihagen, Frede ;
Nordsletten, Lars ;
Madsen, Jan Erik .
BMJ-BRITISH MEDICAL JOURNAL, 2007, 335 (7632) :1251-1254
[10]
Internal Screw Fixation Compared with Bipolar Hemiarthroplasty for Treatment of Displaced Femoral Neck Fractures in Elderly Patients [J].
Gjertsen, J. -E. ;
Vinje, T. ;
Engesaeter, L. B. ;
Lie, S. A. ;
Havelin, L. I. ;
Furnes, O. ;
Fevang, J. M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (03) :619-628