Analysis of carbohydrates by anion exchange chromatography and mass spectrometry

被引:113
作者
Bruggink, C
Maurer, R
Herrmann, H
Cavalli, S
Hoefler, F
机构
[1] Dionex BV, NL-4854 MB Bavel, Netherlands
[2] Dionex Switzerland AG, CH-4600 Olten, Switzerland
[3] Dionex GmbH, D-65510 Idstein, Germany
[4] Dionex Srl, I-20090 Pieve Emanuele, Italy
[5] Dionex Europe Management AG, CH-4600 Olten, Switzerland
关键词
carbohydrates; high performance anion exchange chromatography; pulsed amperometric detection; mass spectrometry; LC; oligosaccharides; inulin; food; beverages;
D O I
10.1016/j.chroma.2005.03.108
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A versatile liquid chromatographic platform has been developed for analysing underivatized carbohydrates using high performance anion exchange chromatography (HPAEC) followed by an inert PEEK splitter that splits the effluent to the integrated pulsed amperometric detector (IPAD) and to an on-line single quadrupole mass spectrometer (MS). Common eluents for HPAEC such as sodium hydroxide and sodium acetate are beneficial for the amperometric detection but not compatible with electrospray ionisation (ESI). Therefore a membrane-desalting device was installed after the splitter and prior to the ESI interface converting sodium hydroxide into water and sodium acetate into acetic acid. To enhance the sensitivity for the MS detection, 0.5 mmol/l lithium chloride was added after the membrane desalter to form lithium adducts of the carbohydrates. To compare sensitivity of IPAD and MS detection glucose, fructose, and sucrose were used as analytes. A calibration with external standards from 2.5 to 1000 pmole was performed showing a linear range over three orders of magnitude. Minimum detection limits (MDL) with IPAD were determined at 5 pmole levels for glucose to be 0.12 pmole, fructose 0.22 pmole and sucrose 0.11 pmole. With MS detection in the selected ion mode (SIM) the lithium adducts of the carbohydrates were detected obtaining MDL's for glucose of 1.49 pmole, fructose 1.19 pmole, and sucrose 0.36 pmole showing that under these conditions IPAD is 3-10 times more sensitive for those carbohydrates. The applicability of the method was demonstrated analysing carbohydrates in real world samples such as chicory inulin where polyfructans up to a molecular mass of 7000 g/mol were detected as quadrupoly charged lithium adducts. Furthermore mono-, di-, tri-, and oligosaccharides were detected in chicory coffee, honey and beer samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 109
页数:6
相关论文
共 14 条
[1]   High-sensitivity and high-resolution methods for glycoprotein analysis [J].
Anumula, KR .
ANALYTICAL BIOCHEMISTRY, 2000, 283 (01) :17-26
[2]   Carbohydrate analysis by high-performance anion-exchange chromatography with pulsed amperometric detection: The potential is still growing [J].
Cataldi, TRI ;
Campa, C ;
De Benedetto, GE .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (08) :739-758
[3]  
De Leenheer L., 1996, Carbohydrates as organic raw materials III, P67, DOI [10.1002/9783527614899, DOI 10.1002/9783527614899]
[4]   A SYSTEMATIC NOMENCLATURE FOR CARBOHYDRATE FRAGMENTATIONS IN FAB-MS MS SPECTRA OF GLYCOCONJUGATES [J].
DOMON, B ;
COSTELLO, CE .
GLYCOCONJUGATE JOURNAL, 1988, 5 (04) :397-409
[6]   CARBOHYDRATE ANALYSIS OF GLYCOPROTEINS - A REVIEW [J].
LEE, KB ;
LOGANATHAN, D ;
MERCHANT, ZM ;
LINHARDT, RJ .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1990, 23 (01) :53-80
[7]   HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY FOR CARBOHYDRATE ANALYSIS [J].
LEE, YC .
ANALYTICAL BIOCHEMISTRY, 1990, 189 (02) :151-162
[8]   Improved long-term reproducibility for pulsed amperometric detection of carbohydrates via a new quadruple-potential waveform [J].
Rocklin, RD ;
Clarke, AP ;
Weitzhandler, M .
ANALYTICAL CHEMISTRY, 1998, 70 (08) :1496-1501
[9]   MAXIMIZING SIGNAL-TO-NOISE RATIO IN DIRECT-CURRENT AND PULSED AMPEROMETRIC DETECTION [J].
ROCKLIN, RD ;
TULLSEN, TR ;
MARUCCO, MG .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :109-114
[10]   Improvements to in-line desalting of oligosaccharides separated by high-pH anion exchange chromatography with pulsed amperometric detection [J].
Thayer, JR ;
Rohrer, JS ;
Avdalovic, N ;
Gearing, RP .
ANALYTICAL BIOCHEMISTRY, 1998, 256 (02) :207-216