Do the Y-set and double-bag systems reduce the incidence of CAPD peritonitis? A systematic review of randomized controlled trails

被引:63
作者
Daly, CD [1 ]
Campbell, MK
MacLeod, AM
Cody, DJ
Vale, LD
Grant, AM
Donaldson, C
Wallace, SA
Lawrence, PD
Khan, IH
机构
[1] Univ Aberdeen, Dept Med & Therapeut, Aberdeen AB25 2ZD, Scotland
[2] Univ Aberdeen, Hlth Serv Res Unit, Aberdeen AB25 2ZD, Scotland
[3] Univ Aberdeen, Hlth Econ Res Unit, Aberdeen AB25 2ZD, Scotland
[4] Univ Aberdeen, Med Sch Lib, Aberdeen AB25 2ZD, Scotland
关键词
CAPD; double bag; peritonitis; randomized controlled trials; systematic review; Y-set;
D O I
10.1093/ndt/16.2.341
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Peritonitis is the most frequent serious complication of continuous ambulatory peritoneal dialysis (CAPD). It has a major influence on the number of patients switching from CAPD to haemodialysis and has probably restricted the wider acceptance and uptake of CAPD as an alternative mode of dialysis. This systematic review sought to determine if modifications of the transfer set (Y-set or double-bag systems) used in CAPD exchanges are associated with a reduction ill peritonitis and an improvement in other relevant outcomes. Methods. Based on a comprehensive search strategy, we undertook a systematic review of randomized or quasi-randomized controlled trials comparing double-bag and/or Y-set CAPD exchange systems with standard systems, or comparing double-bag with Y-set systems, in patients with end-stage renal disease (ESRD) treated with CAPD. Only published data were used. Data were abstracted by a single investigator onto a standard form and subsequently enter-ed into Review Manager 4.0.4. Its statistical package, Metaview 3.1, calculated an odds ratio (OR) for dichotomous data and a (weighted) mean difference for continuous data with 95%, confidence intervals. Results. Twelve eligible trials with a total of 991 randomized patients were identified. In trials comparing either the Y-set or double-bag systems with the standard systems, significantly fewer patients (133/363 vs 158/263; OR 0.33, 95% CI 0.24-0.46) experienced peritonitis and the number of patient-months on CAPD per episode of peritonitis was consistently greater. When the double-bag systems were compared with the Y-set systems significantly fewer patients experienced peritonitis (44/154 vs 66/138; OR 0.44, 95% CI 0.27-0.71) and the number of patient-months on CAPD per episode of peritonitis was also greater. Conclusions. Double-bag systems should be the preferred exchange systems in CAPD.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 36 条
[1]  
[Anonymous], 1985, PERITON DIALYSIS B, V5, P19
[2]  
BAILIE GR, 1990, CLIN NEPHROL, V33, P252
[3]  
BALTEAU PR, 1991, PERITON DIALYSIS INT, V11, P131
[4]  
BAZZATO G, 1980, CLIN NEPHROL, V13, P251
[5]   Improving the quality of reporting of randomized controlled trials - The CONSORT statement [J].
Begg, C ;
Cho, M ;
Eastwood, S ;
Horton, R ;
Moher, D ;
Olkin, I ;
Pitkin, R ;
Rennie, D ;
Schulz, KF ;
Simel, D ;
Stroup, DF .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (08) :637-639
[6]  
Buoncristiani U, 1993, Perit Dial Int, V13 Suppl 2, pS139
[7]   Birth and evolution of the ''Y'' set [J].
Buoncristiani, U .
ASAIO JOURNAL, 1996, 42 (01) :8-11
[8]  
BUONCRISTIANI U, 1983, DIALYSIS TRANSPLANT, V12, P14
[9]  
Buoncristiani U, 1980, INT J NEPHROL UROL A, V1, P45
[10]  