CT and PET lung image registration and fusion in radiotherapy treatment planning using the chamfer-matching

被引:56
作者
Cai, JL [1 ]
Chu, JCH
Recine, D
Sharma, M
Nguyen, C
Rodebaugh, R
Saxena, VA
Ali, A
机构
[1] Rush Med Coll, Rush Presbyterian St Lukes Med Ctr, Dept Radiat Oncol & Med Phys, Chicago, IL 60612 USA
[2] Rush Med Coll, Rush Presbyterian St Lukes Med Ctr, Dept Diagnost Radiol & Nucl Med, Chicago, IL 60612 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 43卷 / 04期
关键词
image registration; image fusion; PET image; radiotherapy treatment planning;
D O I
10.1016/S0360-3016(98)00399-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We present a validation study of CT and PET lung image registration and fusion based on the chamfer-matching method, Methods and Materials: The contours of the lung surfaces from CT and PET transmission images were automatically segmented by the thresholding technique. The chamfer-matching technique was then used to register the extracted lung surfaces. Arithmetic means of distance between the two data sets of the pleural surfaces were used as the cost function. Matching was then achieved by iteratively minimizing the cost function through three-dimensional (3D) translation and rotation with an optimization method. Results: Both anatomic thoracic phantom images and clinical patient images were used to evaluate the performance of our registration system. Quantitative analysis from five patients indicates that the registration error in translation was 2-3 mm in the transverse plane, 3-4 mm in the longitudinal direction, and about 1.5 degree in rotation. Typical computing time for chamfer matching is about 1 min. The total time required to register a set of CT and PET lung images, including contour extraction, was generally less than 30 min, Conclusion: We have implemented and validated the chamfer-matching method for CT and PET lung image registration and fusion, Our preliminary results show that the chamfer-matching method for CT and PET images in the lung area is feasible. The described registration system has been used to facilitate target definition and treatment planning in radiotherapy. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:883 / 891
页数:9
相关论文
共 38 条
  • [1] CLINICAL-ASSESSMENT OF THERAPEUTIC EFFECTS ON CANCER USING F-18 2-FLUORO-2-DEOXY-D-GLUCOSE AND POSITRON EMISSION TOMOGRAPHY - PRELIMINARY-STUDY OF LUNG-CANCER
    ABE, Y
    MATSUZAWA, T
    FUJIWARA, T
    ITOH, M
    FUKUDA, H
    YAMAGUCHI, K
    KUBOTA, K
    HATAZAWA, J
    TADA, M
    IDO, T
    WATANUKI, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (04): : 1005 - 1010
  • [2] ALAVI A, 1994, J NUCL MED, V35, P1650
  • [3] Barrow Harry G., 1977, P IMAGE UNDERSTANDIN
  • [4] A NEW METHOD TO DETERMINE DOSE-EFFECT RELATIONS FOR LOCAL LUNG-FUNCTION CHANGES USING CORRELATED SPECT AND CT DATA
    BOERSMA, LJ
    DAMEN, EMF
    DEBOER, RW
    MULLER, SH
    OLMOS, RAV
    HOEFNAGEL, CA
    ROOS, CM
    VANZANDWIJK, N
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 110 - 116
  • [5] HIERARCHICAL CHAMFER MATCHING - A PARAMETRIC EDGE MATCHING ALGORITHM
    BORGEFORS, G
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1988, 10 (06) : 849 - 865
  • [6] DISTANCE TRANSFORMATIONS IN DIGITAL IMAGES
    BORGEFORS, G
    [J]. COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1986, 34 (03): : 344 - 371
  • [7] BORGEFORS G, 1984, P 7 INT C PATT REC M, P1175
  • [8] CAI J, 1994, MED PHYS, V21, P904
  • [9] OPTIMIZATION AND EVALUATION OF LANDMARK-BASED IMAGE CORRELATION
    ENDE, G
    TREUER, H
    BOESECKE, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) : 261 - 271
  • [10] SOLITARY PULMONARY NODULES - DETECTION OF MALIGNANCY WITH PET WITH 2-[F-18]-FLUORO-2-DEOXY-D-GLUCOSE
    GUPTA, NC
    FRANK, AR
    DEWAN, NA
    REDEPENNING, LS
    ROTHBERG, ML
    MAILLIARD, JA
    PHALEN, JJ
    SUNDERLAND, JJ
    FRICK, MP
    [J]. RADIOLOGY, 1992, 184 (02) : 441 - 444