Ultrasound degradation of novel polymer contrast agents

被引:43
作者
El-Sherif, DM [1 ]
Lathia, JD [1 ]
Le, NT [1 ]
Wheatley, MA [1 ]
机构
[1] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A | 2004年 / 68A卷 / 01期
关键词
ultrasound contrast agent; hollow polymer microcapsules; biodegradable PLGA [poly(lactic-co-glycolic; acid; ultrasound-induced degradation; HPLC;
D O I
10.1002/jbm.a.20032
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This report describes an investigation into factors affecting the degradation of novel poly(lactic-co-glycolic acid) (PLGA) contrast agents. Contrast agents fabricated by two different methods and varying in acoustic properties were compared. The effect of ultrasound frequency (5 and 10 MHz) on degradation of the microcapsules was also studied. High-performance liquid chromatography was used to quantify the production of lactic and glycolic acid to monitor agent degradation. The degradation pattern from the microcapsules was found to be closely related to capsule morphology; the more acoustically efficient capsules (maximum enhancement of 25 dB at 5 MHz with 0.004 mg/mL) degraded at a faster rate than those with lower acoustical efficiency (maximum enhancement of 25 dB at 5 MHz only achieved with 0.6 mg/mL). The capsules also degraded fastest when insonated at the frequency at which they gave highest back-scatter. In addition, despite the use of a 50:50 PLGA copolymer, more glycolic than lactic acid was released at early time points, which reflects the greater hydrophilicity of the glycolic acid residues, and greater degradation rate of glycolic acid repeat units. The results from this study provided unique insight into the degradation behavior of hollow PLGA microcapsules, and their potential in ultrasound diagnosis and therapy. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 18 条
[1]  
BROPHY RM, 1990, ENCY PHARM TECHNOLOG, V2, P1
[2]   Development of a novel method for synthesis of a polymeric ultrasound contrast agent [J].
El-Sherif, DM ;
Wheatley, MA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (02) :347-355
[3]   In vitro degradation study of polyester microspheres by a new HPLC method for monomer release determination [J].
Giunchedi, P ;
Conti, B ;
Scalia, S ;
Conte, U .
JOURNAL OF CONTROLLED RELEASE, 1998, 56 (1-3) :53-62
[4]   Mechanisms of polymer degradation and erosion [J].
Gopferich, A .
BIOMATERIALS, 1996, 17 (02) :103-114
[5]   Enhanced immune response after subcutaneous and oral immunization with biodegradable PLGA microspheres [J].
Igartua, M ;
Hernández, RM ;
Esquisabel, A ;
Gascón, AR ;
Calvo, MB ;
Pedraz, JL .
JOURNAL OF CONTROLLED RELEASE, 1998, 56 (1-3) :63-73
[6]   ULTRASOUND-ENHANCED POLYMER DEGRADATION AND RELEASE OF INCORPORATED SUBSTANCES - (CONTROLLED RELEASE DRUG DELIVERY SYSTEMS) [J].
KOST, J ;
LEONG, K ;
LANGER, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (20) :7663-7666
[7]  
KOST J, 1998, MAKROMOL CHEM-M SYMP, V19, P275
[8]   Mass transport enhancement by ultrasound in non-degradable polymeric controlled release systems [J].
Lavon, I ;
Kost, J .
JOURNAL OF CONTROLLED RELEASE, 1998, 54 (01) :1-7
[9]   DEGRADATION OF POLY(D,L-LACTIC ACID) MICROSPHERES - EFFECT OF MOLECULAR-WEIGHT [J].
PARK, TG .
JOURNAL OF CONTROLLED RELEASE, 1994, 30 (02) :161-173
[10]   IMPORTANCE OF IN-VITRO EXPERIMENTAL CONDITIONS ON PROTEIN RELEASE KINETICS, STABILITY AND POLYMER DEGRADATION IN PROTEIN ENCAPSULATED POLY(D,L-LACTIC ACID-CO-GLYCOLIC ACID) MICROSPHERES [J].
PARK, TG ;
LU, WQ ;
CROTTS, G .
JOURNAL OF CONTROLLED RELEASE, 1995, 33 (02) :211-222