Applicability of various brands of mixed-phase extraction columns for opiate extraction from blood and serum

被引:25
作者
Bogusz, MJ
Maier, RD
SchiwyBochat, KH
Kohls, U
机构
[1] Institute of Forensic Medicine, Klinikum RWTH, Aachen University of Technology
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1996年 / 683卷 / 02期
关键词
morphine; 6-monoacetylmorphine; codeine;
D O I
10.1016/0378-4347(96)00120-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Four commercially available types of mixed-phase solid-phase extraction (SPE) columns (Bond Elut Certify, Isolute Confirm HCX, Chromabond Drug and Bakerbond Narc-2) were examined in order to compare the extraction efficiencies and chromatographic purity of extracts. The absolute recovery of morphine, 6-monoacetylmorphine and codeine was examined in blood and serum (ten samples each at two concentration levels), using SPE columns of the same batch. GC-MS (ion trap) and HPLC with amperometric detection were used for quantitation. A distinct variability in extraction recovery was observed among the same batches of all brands of SPE columns. All extracts were chromatographically pure and no interfering peaks were observed, neither in GC-MS nor in HPLC examinations, but in some extracts large peaks of plasticizers were identified. The measurements of how velocities of the same samples of blood or serum through the SPE columns of the same batch showed very large variability of random character. The morphometric analysis of particles was performed for two batches of each sort of SPE columns by means of an image analysing system. Symmetrical distribution of particle size was observed only in Chromabond MN Drug packing, while in other cartridges large fractions of fine particles and nonhomogenous distribution were found. Only in one case the morphometric findings were pretty concordant with the data available from the manufacturer; in two cases, observed data varied considerably from that expected, and in one case no information was available at all. The study showed generally that there was room for improvement in the quality of mixed-phase SPE columns.
引用
收藏
页码:177 / 188
页数:12
相关论文
共 34 条
  • [1] A REVIEW OF SOLID-PHASE EXTRACTION - BASIC PRINCIPLES AND NEW DEVELOPMENTS
    BERRUETA, LA
    GALLO, B
    VICENTE, F
    [J]. CHROMATOGRAPHIA, 1995, 40 (7-8) : 474 - 483
  • [2] IMPACT OF BIOLOGICAL MATRIX, DRUG CONCENTRATION, AND METHOD OF ISOLATION ON DETECTABILITY AND VARIABILITY OF RETENTION INDEX VALUES IN GAS-CHROMATOGRAPHY
    BOGUSZ, M
    WIJSBEEK, J
    FRANKE, JP
    DEZEEUW, RA
    GIERZ, J
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1985, 9 (02) : 49 - 54
  • [3] BOGUSZ M, 1992, TOXICHEM, V59, P2
  • [4] BOGUSZ M, 1995, DROGENKONTROLLE HEUT, P59
  • [5] SOLID-PHASE EXTRACTION CONDITIONS FOR THE SELECTIVE ISOLATION OF DRUGS FROM BIOLOGICAL-FLUIDS PREDICTED USING LIQUID-CHROMATOGRAPHY
    CASAS, M
    BERRUETA, LA
    GALLO, B
    VICENTE, F
    [J]. CHROMATOGRAPHIA, 1992, 34 (1-2) : 79 - 82
  • [6] CEDER G, 1991, P 29 TIAFT M COP, P193
  • [7] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MORPHINE, MORPHINE-3-GLUCURONIDE, MORPHINE-6-GLUCURONIDE AND CODEINE IN BIOLOGICAL SAMPLES USING MULTIWAVELENGTH FORWARD OPTICAL-DETECTION
    CHARI, G
    GULATI, A
    BHAT, R
    TEBBETT, IR
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 571 (1-2): : 263 - 270
  • [8] CHEN XH, 1993, J FORENSIC SCI, V38, P668
  • [9] STUDY OF LOT-TO-LOT REPRODUCIBILITIES OF BOND ELUT CERTIFY AND CLEAN SCREEN DAU MIXED-MODE SOLID-PHASE EXTRACTION COLUMNS IN THE EXTRACTION OF DRUGS FROM WHOLE-BLOOD
    CHEN, XH
    FRANKE, JP
    WIJSBEEK, J
    DEZEEUW, RA
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 617 (01): : 147 - 151
  • [10] ISOLATION OF ACIDIC, NEUTRAL, AND BASIC DRUGS FROM WHOLE-BLOOD USING A SINGLE MIXED-MODE SOLID-PHASE EXTRACTION COLUMN
    CHEN, XH
    FRANKE, JP
    WIJSBEEK, J
    DEZEEUW, RA
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1992, 16 (06) : 351 - 355