Development of a simulator for endovascular repair of abdominal aortic aneurysms

被引:27
作者
Chong, CK
How, TV [1 ]
Black, RA
Shortland, AP
Harris, PL
机构
[1] Univ Liverpool, Dept Clin Engn, Liverpool L69 3BX, Merseyside, England
[2] Royal Liverpool Univ Hosp, Dept Vasc Surg, Liverpool, Merseyside, England
关键词
training simulator; endoluminal repair; stent-grafts; simulating fluoroscopic imaging;
D O I
10.1114/1.66
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The design and development of a simulator for endovascular repair of abdominal aortic aneurysm (AAA) is described. The simulator consists of an interchangeable model of a human AAA based on computed tomography data and is produced by means of computer-aided design and manufacture (CAD/CAM) techniques. The model has renal, iliac, and femoral arteries. and is perfused with a temperature controlled blood-analog fluid under simulated physiological flow conditions. "Fluoroscopic imaging" is simulated by a computerized imaging system that uses visible Light. A movable video camera relays images in die antero-posterior and lateral planes of the AAA to a monitor. The imaging system allows "arteriography" and "road-mapping" to be performed so as to facilitate accurate deployment of endovascular stent-grafts. The system has been used for teaching and demonstrating endovascular techniques to clinicians, as well as the evaluation of new stentgraft devices. Its successful incorporation into endovascular workshops has demonstrated its role in the training of clinicians in endovascular repair of AAA. (C) 1998 Biomedical Engineering Society. [S0090-6964(98)01605-1].
引用
收藏
页码:798 / 802
页数:5
相关论文
共 17 条
[1]
Reporting standards for infrarenal endovascular abdominal aortic aneurysm repair [J].
Ahn, SS ;
Rutherford, RB ;
Johnston, KW ;
May, J ;
Veith, FJ ;
Baker, JD ;
Ernst, CB ;
Moore, WS .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (02) :405-410
[2]
INFRARENAL AORTIC-ANEURYSM STRUCTURE - IMPLICATIONS FOR TRANSFEMORAL REPAIR [J].
CHUTER, TAM ;
GREEN, RM ;
OURIEL, K ;
DEWEESE, JA .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (01) :44-50
[3]
ERNST CB, 1993, NEW ENGL J MED, V328, P1167
[4]
FABRICATION OF VASCULAR REPLICAS FROM MAGNETIC-RESONANCE IMAGES [J].
FRIEDMAN, MH ;
KUBAN, BD ;
SCHMALBROCK, P ;
SMITH, K ;
ALTAN, T .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (03) :364-366
[5]
Green R M, 1995, Cardiovasc Surg, V3, P101, DOI 10.1016/0967-2109(95)90881-5
[6]
HARRIS PL, 1992, BRIT J SURG, V303, P697
[7]
INGOLDBY CJH, 1986, BRIT J SURG, V73, P552
[8]
INTRALUMINAL BYPASS OF ABDOMINAL AORTIC-ANEURYSM - FEASIBILITY STUDY [J].
LABORDE, JC ;
PARODI, JC ;
CLEM, MF ;
TIO, FO ;
BARONE, HD ;
RIVERA, FJ ;
ENCARNACION, CE ;
PALMAZ, JC .
RADIOLOGY, 1992, 184 (01) :185-190
[9]
McDonald D. A., 1974, BLOOD FLOW ARTERIES
[10]
PERCUTANEOUSLY PLACED ENDOVASCULAR GRAFTS FOR AORTIC-ANEURYSMS - FEASIBILITY STUDY [J].
MIRICH, D ;
WRIGHT, KC ;
WALLACE, S ;
YOSHIOKA, T ;
LAWRENCE, DD ;
CHARNSANGAVEJ, C ;
GIANTURCO, C .
RADIOLOGY, 1989, 170 (03) :1033-1037