Short-wavelength automated perimetry and retinal nerve fiber layer evaluation in suspected cases of glaucoma

被引:42
作者
Polo, V [1 ]
Abecia, E [1 ]
Pablo, LE [1 ]
Pinilla, I [1 ]
Larrosa, JM [1 ]
Honrubia, FM [1 ]
机构
[1] Hosp Miguel Servet, Dept Ophthalmol, Zaragoza 50009, Spain
关键词
D O I
10.1001/archopht.116.10.1295
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To determine if short-wavelength automated perimetry (SWAP) provides evidence that indicates early functional losses in ocular hypertensive subjects and to establish a direct comparison with early structural abnormalities in the retinal nerve fiber layer (RNFL). Methods: A total of 160 eyes belonging to 83 patients with ocular hypertension (intraocular pressure >21 mm Hg and normal results on standard automated perimetry evaluation), on which a SWAP and RNFL study were performed, were examined. One hundred twenty-eight age-matched subjects without ocular hypertension were evaluated to establish the 95% and 99% confidence intervals at each of the 76 exploration points of the SWAP test. Results: The RNFL study results were normal in 83 cases (51.8%) and pathologic in 77 cases (48.1%). The SWAP results were pathologic in 57 cases (35.6%). Significant differences (P<.001) were observed when comparing the distribution of normal and pathologic SWAP results among the types of defects in the RNFL (focal wedge, diffuse atrophy, and mixed atrophy). Conclusions: Short-wavelength automated perimetry is a useful test for the early detection of visual field losses. It is more sensitive than standard automated perimetry and provides a high association with RNFL assessment, which has proved capable of detecting signs of glaucomatous damage several years before the onset of the typical visual field defects.
引用
收藏
页码:1295 / 1298
页数:4
相关论文
共 24 条
[1]  
ABECIA E, 1995, ANN OPHTHALMOL-GLAUC, V27, P203
[2]  
ABECIA E, 1996, ARCH SOC ESP OFTALMO, V70, P489
[3]   RATE AND PATTERN OF NEURORETINAL RIM AREA DECREASE IN OCULAR HYPERTENSION AND GLAUCOMA [J].
AIRAKSINEN, PJ ;
TUULONEN, A ;
ALANKO, HI .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (02) :206-210
[4]  
Gonzalez I, 1997, ANN OPHTHALMOL-GLAUC, V29, P122
[5]  
HERON G, 1988, INVEST OPHTH VIS SCI, V29, P64
[6]  
HONRUBIA FM, 1991, INT OPHTHALMOL, V13, P57
[7]  
Johnson C A, 1996, Curr Opin Ophthalmol, V7, P54, DOI 10.1097/00055735-199604000-00010
[8]   BLUE-ON-YELLOW PERIMETRY CAN PREDICT THE DEVELOPMENT OF GLAUCOMATOUS VISUAL-FIELD LOSS [J].
JOHNSON, CA ;
ADAMS, AJ ;
CASSON, EJ ;
BRANDT, JD .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (05) :645-650
[9]  
JOHNSON CA, 1993, PERIMETRY UPDATE 1992/1993, P459
[10]   SHORT-WAVELENGTH AUTOMATED PERIMETRY IN LOW-RISK, MEDIUM-RISK, AND HIGH-RISK OCULAR HYPERTENSIVE EYES - INITIAL BASE-LINE RESULTS [J].
JOHNSON, CA ;
BRANDT, JD ;
KHONG, AM ;
ADAMS, AJ .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (01) :70-76