Pulsed digital holography for deformation measurements on biological tissues

被引:48
作者
Schedin, S
Pedrini, G
Tizian, HJ
机构
[1] Univ Stuttgart, Inst Tech Opt, D-70569 Stuttgart, Germany
[2] Lulea Univ Technol, Div Expt Mech, SE-97187 Lulea, Sweden
关键词
D O I
10.1364/AO.39.002853
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Digital holograms are recorded of biological tissues by use of a Q-switched double-pulsed ruby laser. An image-plane digital holography setup is used with a CCD camera for capturing two holograms with a short time separation (20-800 mu s). Subtraction of the phase distribution in two digital holograms yield a fringe phase map that shows the change in deformation of the tissue surface between the recordings. Experiments are pet-formed on tissue from a pig that was excited by a short-shock pulse and on a human hand that was excited by sinusoidal stimulation. Results when the object is imaged through an endoscope are also presented. The technique could be an approach for measuring parameters like elasticity on biological tissues. (C) 2000 Optical Society of America OCIS codes: 090.2880, 170.4580.
引用
收藏
页码:2853 / 2857
页数:5
相关论文
共 12 条
[1]   Study of transient deformations with pulsed TV holography: Application to crack detection [J].
Fernandez, A ;
Moore, AJ ;
PerezLopez, C ;
Doval, AF ;
BlancoGarcia, J .
APPLIED OPTICS, 1997, 36 (10) :2058-2065
[2]   Tomographic reconstruction of transient acoustic fields recorded by pulsed TV holography [J].
Gren, P ;
Schedin, S ;
Li, XD .
APPLIED OPTICS, 1998, 37 (05) :834-840
[3]   Detection of breast lesions by holographic interferometry [J].
Hong, HD ;
Sheffer, DB ;
Loughry, CW .
JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (03) :368-375
[4]   Digital double pulse-TV-holography [J].
Pedrini, G ;
Tiziani, HJ ;
Zou, YL .
OPTICS AND LASERS IN ENGINEERING, 1997, 26 (2-3) :199-219
[5]   PULSED LASER HOLOGRAPHY IN STUDIES OF BONE MOTIONS AND DEFORMATIONS [J].
PRYPUTNIEWICZ, RJ .
OPTICAL ENGINEERING, 1985, 24 (05) :832-839
[6]   All-fibre pulsed digital holography [J].
Schedin, S ;
Pedrini, G ;
Tiziani, HJ ;
Santoyo, FM .
OPTICS COMMUNICATIONS, 1999, 165 (4-6) :183-188
[7]   DOUBLE-PULSE SUBTRACTION TV HOLOGRAPHY [J].
SPOOREN, R .
OPTICAL ENGINEERING, 1992, 31 (05) :1000-1007
[8]   FOURIER-TRANSFORM METHOD OF FRINGE-PATTERN ANALYSIS FOR COMPUTER-BASED TOPOGRAPHY AND INTERFEROMETRY [J].
TAKEDA, M ;
INA, H ;
KOBAYASHI, S .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1982, 72 (01) :156-160
[9]  
Vest C.M., 1979, HOLOGRAPHIC INTERFER
[10]   A new dynamic endoscopic holographic interferometer for in-vivo medical imaging metrology [J].
von Bally, G ;
Kemper, B ;
Merker, A ;
Lai, S .
18TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR THE NEXT MILLENNIUM, TECHNICAL DIGEST, 1999, 3749 :393-394