Polypropylene as a reinforcement in pelvic surgery is not inert: comparative analysis of 100 explants

被引:98
作者
Clave, Arnaud [2 ]
Yahi, Hannah [3 ]
Hammou, Jean-Claude [4 ]
Montanari, Suzelei [5 ]
Gounon, Pierre [6 ]
Clave, Henri [1 ]
机构
[1] Clin St George, Dept Chirurg Gynecol, F-06000 Nice, France
[2] Univ Bretagne Occidentale, CHRU Brest Fac Med, Serv Chirurg Pr Lefevre, Brest, France
[3] CHRU Lille, Serv Gynecol Pr Cosson, Lille, France
[4] Lab Anatomopathol, Nice, France
[5] Dept Res & Dev, Covidien, Trevoux, France
[6] Univ Nice Sophia Antipolis, CCMA, Nice, France
关键词
Biomaterials; Histological examination; Pelvic floor disorders; Polyester; Polypropylene; Vaginal surgery; URINARY-INCONTINENCE; HUMAN-EYE; MESH; PROLAPSE; SAFETY; EFFICACY;
D O I
10.1007/s00192-009-1021-8
中图分类号
R71 [妇产科学];
学科分类号
100211 [妇产科学];
摘要
Currently, most implants used for reinforcement in surgical treatment of pelvic floor disorders are knitted monofilament polypropylene (PP). While previously recognized as inert, PP is associated with high complication rates. Some recent literature suggests polyester prosthetics based on poly(ethylene terephthalate) (PET), which may be more inert in vivo. A sample of 100 implants explanted from patients due to complications was examined to evaluate the relative degradation characteristics of PP and PET prosthetics. Histological, microscopic (scanning electron microscopy, SEM) and chemical analysis (Fourier transform infrared (FTIR) spectroscopy and differential scanning calorimetry (DSC)) were conducted on these explants. Poly(ethylene terephtahlate) explants appeared to sustain less degradation in vivo than the PP explants observed in this cohort. This is the first study to evaluate synthetic implants used in a vaginal approach for pelvic floor reinforcement. The study provides evidence contrary to published literature characterizing PP as inert in such applications. Additionally, the study suggests the need for clinical trials comparatively investigating the performance of new types of monofilament prosthetics, such as those comprising PET.
引用
收藏
页码:261 / 270
页数:10
相关论文
共 24 条
[1]
ALTMAN AJ, 1986, ANN OPHTHALMOL, V18, P182
[2]
Amid PK, 1997, CHIRURG, V68, P959, DOI 10.1007/s001040050302
[3]
Bader G, 2006, Gynecol Obstet Fertil, V34, P292, DOI 10.1016/j.gyobfe.2006.02.016
[4]
Comparison between monofilament and multifilament polypropylene tapes in urinary incontinence [J].
Bafghi, A ;
Valerio, L ;
Benizri, EI ;
Trastour, C ;
Benizri, EJ ;
Bongain, A .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2005, 122 (02) :232-236
[5]
Comparison of polypropylene and polyethylene terephthalate (Dacron) meshes for abdominal wall hernia repair: A chemical and morphological study [J].
Bracco P. ;
Brunella V. ;
Trossarelli L. ;
Coda A. ;
Botto-Micca F. .
Hernia, 2005, 9 (1) :51-55
[6]
Perineal cellulitis following trans-obturator sub-urethral tape Uratape® [J].
Caquant, F ;
Collinet, P ;
Deruelle, P ;
Lucot, JP ;
Cosson, M .
EUROPEAN UROLOGY, 2005, 47 (01) :108-110
[7]
Safety of trans vaginal mesh procedure: Retrospective study of 684 patients [J].
Caquant, Frederic ;
Collinet, Pierre ;
Debodinance, Philippe ;
Berrocal, Juan ;
Garbin, Olivier ;
Rosenthal, Claude ;
Clave, Henri ;
Villet, Richard ;
Jacquetin, Bernard ;
Cosson, Michel .
JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2008, 34 (04) :449-456
[8]
CLAYMAN HM, 1981, OPHTHALMOLOGY, V88, P959
[9]
CODA A, 2003, HERNIA, V7, P44
[10]
Oxidation of orthopaedic UHMWPE [J].
Costa, L ;
Jacobson, K ;
Bracco, P ;
del Prever, EMB .
BIOMATERIALS, 2002, 23 (07) :1613-1624