RETRACTED: Detection of human apolipoprotein E genotypes by DNA biosensors coupled with PCR (Retracted article. See vol. 329, pg. 157, 2003)

被引:27
作者
Marrazza, G
Tombelli, S
Mascini, N
Manzoni, A
机构
[1] SEAC RADIM Grp, Dept Res & Dev, I-50041 Florence, Italy
[2] Dipartimento Sanit Pubbl Epidemiol, Chim Anal Ambientale, Sez Chim Analit, I-50121 Florence, Italy
关键词
polymorphism; apolipoprotein E; electrochemical biosensor; DNA hybridization; piezoelectric biosensor;
D O I
10.1016/S0009-8981(01)00454-5
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Apolipoprotein E (apoE) is an important constituent of several plasma lipoproteins and has been associated with the risk of developing cardiovascular diseases and in familiar type In hyperlipoproteinemia. We developed new procedures for the detection of apolipoprotein E polymorphism in human blood based on coupling DNA electrochemical or piezoelectric sensors with polymerase chain reaction (PCR), The electrochemical sensor was obtained by immobilizing single-stranded oligonucleotides onto graphite screen-printed electrodes by adsorption at controlled potential. The hybridization reaction that occurred on the electrode surface was evidenced by chronopotentiometric stripping analysis-using daunomycin as indicator. In the piezoelectric sensor, biotinylated 23-mer probes were immobilized on the streptavidin-coated gold surface of a quartz crystal; streptavidin was covalently bound to the thiol/dextran modified gold surface. The hybridization of the immobilized probes with complementary and mismatched DNA was investigated. With the use of two different probes, it was possible to investigate both positions in which apoE polymorphism takes place and consequently, to distinguish the different genotypes, The procedure was validated with both kinds of biosensor with a reference method based on polyacrilamide gel electrophoresis. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 23 条
[1]   Enzyme-amplified amperometric detection of hybridization and of a single base pair mutation in an 18-base oligonucleotide on a 7-μm-diameter microelectrode [J].
Caruana, DJ ;
Heller, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (04) :769-774
[2]  
DeBellis G, 1997, CLIN CHEM, V43, P1321
[3]   GENOTYPING AND SEQUENCE-ANALYSIS OF APOLIPOPROTEIN-E ISOFORMS [J].
EMI, M ;
WU, LL ;
ROBERTSON, MA ;
MYERS, RL ;
HEGELE, RA ;
WILLIAMS, RR ;
WHITE, R ;
LALOUEL, JM .
GENOMICS, 1988, 3 (04) :373-379
[4]  
FUNKE H, 1986, CLIN CHEM, V32, P1285
[5]  
Furtado LM, 1998, ANALYST, V123, P1937
[6]   NOVEL DNA SENSOR FOR ELECTROCHEMICAL GENE DETECTION [J].
HASHIMOTO, K ;
ITO, K ;
ISHIMORI, Y .
ANALYTICA CHIMICA ACTA, 1994, 286 (02) :219-224
[7]  
HIXSON JE, 1990, J LIPID RES, V31, P545
[8]  
LAITINEN J, 1994, BIOTECHNIQUES, V17, P316
[9]  
Marrazza G, 2000, CLIN CHEM, V46, P31
[10]   Disposable DNA electrochemical sensor for hybridization detection [J].
Marrazza, G ;
Chianella, I ;
Mascini, M .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (01) :43-51