Embolic protection in patients undergoing transaortic transcatheter aortic valve replacement: initial experience with the TriGuard HDH embolic deflection device

被引:6
作者
Campelo-Parada, Francisco [1 ]
Regueiro, Ander [1 ]
Dumont, Eric [1 ]
DeLarochelliere, Robert [1 ]
Paradis, Jean-Michel [1 ]
Mohammadi, Siamak [1 ]
Doyle, Daniel [1 ]
Rodes-Cabau, Josep [1 ]
机构
[1] Univ Laval, Quebec Heart & Lung Inst, 2725 Chemin Ste Foy, Quebec City, PQ G1V 4GS, Canada
关键词
IMPLANTATION; STENOSIS; TRIAL;
D O I
10.1111/jocs.12822
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
BACKGROUNDStroke remains one of the most worrisome complications following transcatheter aortic valve replacement (TAVR). This pilot study evaluates the safety, feasibility, and exploratory efficacy of the TriGuard HDH embolic deflection device (Keystone Heart Ltd., Caesarea, Israel) in patients undergoing transaortic TAVR. METHODSA total of 10 patients (median age: 81 years, STS score: 9.65.6%) undergoing transaortic TAVR were included. All 30-day events were recorded and defined according to Valve Academic Research Consortium-2 criteria. Cerebral diffusion-weighted magnetic resonance imaging exams were planned preprocedure and within 10days post-TAVR. The results of the magnetic resonances were analyzed in an independent core laboratory blinded to clinical data. Neurocognitive evaluation tests (Montreal Cognitive Assessment, Cogstate, Digit Symbol Substitution Test, Word Fluency Test, and Trailmaking tests) were performed at baseline, and within 10 and 30 days post-TAVR. RESULTSThe TriGuard HDH device was successfully deployed in all patients without complications. There was one procedural major vascular complication unrelated to the study device, and no clinically apparent stroke events were observed at 30-day follow-up. Cerebral diffusion weighted magnetic resonance imaging exams were performed in six patients at 7.5 +/- 1.9days post-TAVR showing the presence of new ischemic lesions in five patients (83.3%), which were single lesions in 60% of these individuals. Paired neurocognitive evaluation tests demonstrated no significant changes in neurocognitive parameters over time. CONCLUSIONSThis study shows the safety and feasibility of using the TriGuard HDH embolic protection device in transaortic TAVR. Further studies are warranted to determine the efficacy of embolic protection in this population.
引用
收藏
页码:617 / 622
页数:6
相关论文
共 23 条
[1]
Abdul-Jawad Altisent O, 2016, REV ESP CAR IN PRESS
[2]
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[3]
Embolic Cerebral Insults After Transapical Aortic Valve Implantation Detected by Magnetic Resonance Imaging [J].
Arnold, Martin ;
Schulz-Heise, Susanne ;
Achenbach, Stephan ;
Ott, Sabine ;
Doerfler, Arnd ;
Ropers, Dieter ;
Feyrer, Richard ;
Einhaus, Friedrich ;
Loders, Sabrina ;
Mahmoud, Faidi ;
Roerick, Olaf ;
Daniel, Werner G. ;
Weyand, Michael ;
Ensminger, Stephan M. ;
Ludwig, Josef .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) :1126-1132
[4]
Predictors of Early Cerebrovascular Events in Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement [J].
Auffret, Vincent ;
Regueiro, Ander ;
Del Trigo, Maria ;
Altisent, Omar Abdul-Jawad ;
Campelo-Parada, Francisco ;
Chiche, Olivier ;
Puri, Rishi ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (07) :673-684
[5]
Safety and performance of a novel embolic deflection device in patients undergoing transcatheter aortic valve replacement: results from the DEFLECT I study [J].
Baumbach, Andreas ;
Mullen, Michael ;
Brickman, Adam M. ;
Aggarwal, Suneil K. ;
Pietras, Cody G. ;
Forrest, John K. ;
Hildick-Smith, David ;
Meller, Stephanie M. ;
Gambone, Louise ;
den Heijer, Peter ;
Margolis, Pauliina ;
Voros, Szilard ;
Lansky, Alexandra J. .
EUROINTERVENTION, 2015, 11 (01) :75-84
[6]
Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status [J].
Fairbairn, Timothy A. ;
Mather, Adam N. ;
Bijsterveld, Petra ;
Worthy, Gillian ;
Currie, Stuart ;
Goddard, Anthony J. P. ;
Blackman, Daniel J. ;
Plein, Sven ;
Greenwood, John P. .
HEART, 2012, 98 (01) :18-23
[7]
Evaluation of the Usability of a Brief Computerized Cognitive Screening Test in Older People for Epidemiological Studies [J].
Fredrickson, J. ;
Maruff, P. ;
Woodward, M. ;
Moore, L. ;
Fredrickson, A. ;
Sach, J. ;
Darby, D. .
NEUROEPIDEMIOLOGY, 2010, 34 (02) :65-75
[8]
Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis The CLEAN-TAVI Randomized Clinical Trial [J].
Haussig, Stephan ;
Mangner, Norman ;
Dwyer, Michael G. ;
Lehmkuhl, Lukas ;
Luecke, Christian ;
Woitek, Felix ;
Holzhey, David M. ;
Mohr, Friedrich W. ;
Gutberlet, Matthias ;
Zivadinov, Robert ;
Schuler, Gerhard ;
Linke, Axel .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (06) :592-601
[9]
The transaortic approach for transcatheter aortic valve implantation: a valid alternative to the transapical access in patients with no peripheral vascular option. A single center experience [J].
Hayashida, Kentaro ;
Romano, Mauro ;
Lefevre, Thierry ;
Chevalier, Bernard ;
Farge, Arnaud ;
Hovasse, Thomas ;
Le Houerou, Daniel ;
Morice, Marie-Claude .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 44 (04) :692-699
[10]
Silent and Apparent Cerebral Ischemia After Percutaneous Transfemoral Aortic Valve Implantation A Diffusion-Weighted Magnetic Resonance Imaging Study [J].
Kahlert, Philipp ;
Knipp, Stephan C. ;
Schlamann, Marc ;
Thielmann, Matthias ;
Al-Rashid, Fadi ;
Weber, Marcel ;
Johansson, Uw ;
Wendt, Daniel ;
Jakob, Heinz G. ;
Forsting, Michael ;
Sack, Stefan ;
Erbel, Raimund ;
Eggebrecht, Holger .
CIRCULATION, 2010, 121 (07) :870-878