Stent fracture after endoluminal repair of a carotid artery pseudoaneurysm

被引:28
作者
de Vries, JPPM
Meijer, RW
van den Berg, JC
Meijer, JMR
van de Pavoordt, EDWM
机构
[1] St Antonius Hosp, Dept Vasc Surg, NL-3435 CM Nieuwegein, Netherlands
[2] St Antonius Hosp, Dept Intervent Radiol, NL-3435 CM Nieuwegein, Netherlands
关键词
internal carotid artery; pseudoaneurysm; stent-graft; endovascular repair;
D O I
10.1583/05-1597.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To present a case in which a covered stent fractured 7 months after implantation in the internal carotid artery (ICA). Case Report: A 59-year-old man presented with a large traumatic pseudoaneurysm of the left ICA. Seven months after successful treatment with a covered Symbiot stent, clinical complaints recurred because the pseudoaneurysm recanalized due to fracture of the stent at its midsection. Surgical stent explantation was needed, with polytetrafluoroethylene graft reconstruction of the ICA. No complications occurred in the periprocedural period. A control duplex scan 12 months later showed exclusion of the pseudoaneurysm and no graft-related complications. Conclusions: This case demonstrates an as yet unreported complication of stent-grafting in a carotid artery.
引用
收藏
页码:612 / 615
页数:4
相关论文
共 17 条
[1]
Bush RL, 2001, J ENDOVASC THER, V8, P53, DOI 10.1583/1545-1550(2001)008<0053:ESPACE>2.0.CO
[2]
2
[3]
Infected postcarotid endarterectomy pseudoaneurysms: Retrospective review of a series [J].
El-Sabrout, R ;
Reul, G ;
Cooley, DA .
ANNALS OF VASCULAR SURGERY, 2000, 14 (03) :239-247
[4]
Endovascular management of tandem extracranial internal carotid artery aneurysms with a covered stent [J].
Fischer, B ;
Palkovic, S ;
Wassmann, H ;
Heindel, W ;
Krämer, SC .
JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (06) :739-741
[5]
Mechanical failure of prosthetic human implants: A 10-year experience with aortic stent graft devices [J].
Jacobs, TS ;
Won, J ;
Gravereaux, EC ;
Faries, PL ;
Morrissey, N ;
Teodorescu, VJ ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (01) :16-26
[6]
Longitudinal Stent fracture 11 months after implantation in the left pulmonary artery and successful management by a stent-in-stent maneuver [J].
Knirsch, W ;
Haas, NA ;
Lewin, MAG ;
Uhlemann, F .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (01) :116-118
[7]
Kubaska SM, 2003, J ENDOVASC THER, V10, P182, DOI 10.1583/1545-1550(2003)010<0182:ICAPTW>2.0.CO
[8]
2
[9]
Endoluminal repair of internal carotid artery aneurysm: A feasible but hazardous procedure [J].
May, J ;
White, GH ;
Waugh, R ;
Brennan, J .
JOURNAL OF VASCULAR SURGERY, 1997, 26 (06) :1055-1060
[10]
Endoluminal repair of carotid artery pseudoaneurysms: A word of caution [J].
McCready, RA ;
Divelbiss, JL ;
Bryant, MA ;
Denardo, AJ ;
Scott, JA .
JOURNAL OF VASCULAR SURGERY, 2004, 40 (05) :1020-1023