Effects of temperature steps on human skin physiology and thermal sensation response

被引:208
作者
Chen, Chen-Peng [2 ]
Hwang, Ruey-Lung [1 ]
Chang, Shih-Yin [2 ]
Lu, Yu-Ting [2 ]
机构
[1] Natl United Univ, Dept Architecture, Kung Ching Li 36003, Miaoli, Taiwan
[2] China Med Univ, Dept Occupat Safety & Hlth, Taichung 40402, Taiwan
关键词
Temperature step; Climate chamber experiment; Skin physiological indicators; Transepidermal water loss; Thermal sensation; Transient thermal comfort; EQUIVALENT TEMPERATURE; TRANSITIONAL SPACES; COMFORT REQUIREMENTS; ENVIRONMENTS; HEAT; HAND; MOISTURE; FINGER; TAIWAN; INDEX;
D O I
10.1016/j.buildenv.2011.05.021
中图分类号
TU [建筑科学];
学科分类号
081407 [建筑环境与能源工程];
摘要
Air-conditioning is frequently used as a means of adjusting indoor thermal environment in hot-and-humid areas. However, when entering an air-conditioned building from outdoors people may experience thermal discomfort and risk health consequence if the instantaneous change of air temperature exceeds the thermoregulatory capacity. A study was conducted to investigate the alteration in thermal perception and in thermoregulation that simultaneously occurred in response to temperature step in a thermal transient. In this study, two temperature down-steps from 32/28 to 24 degrees C and an up-step from 20 to 24 degrees C were created in a climatic chamber consisting of two microclimate-controlled rooms, and subjects were evaluated for change in thermal sensation as well as in skin physiological properties, including skin capillary blood flow (SCBF), skin moisture, transepidermal water loss (TEWL), and skin temperature over the course of acclimation. As the results show, a cold sensation overshot occurred in thermal sensation vote (TSV), skin temperature, and SCBF in 1 min after the temperature dropped from 32 to 24 degrees C. TSV correlated the best with skin temperature (r = 0.60) and moderately with skin moisture and TEWL (r = 0.42-0.54) when the temperature down-step reached 8 degrees C. TEWL acclimated in a two-stage pattern, demonstrating a difference between the sensational change and thermoregulation. The gender-specific influence occurred in thermoregulation but not in subjective sensation. The findings of the study suggest that thermoregulatory burden might be adequately controlled when the temperature step in thermal transition zone is limited to 4 degrees C or lower. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2387 / 2397
页数:11
相关论文
共 34 条
[1]
[Anonymous], [No title captured]
[2]
[Anonymous], 2005, 77302005E ISO
[3]
[Anonymous], 2002, FUNDAMENTALS IND HYG
[4]
*ASHRAE INC, 2004, 552004 ANSIASHRAE
[5]
EFFECT OF LOCAL WARMING ON HAND AND FINGER ARTERY BLOOD VELOCITIES [J].
BERGERSEN, TK ;
ERIKSEN, M ;
WALLOE, L .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 1995, 269 (02) :R325-R330
[6]
CHEN CP, 2010, OCCUP ENV MED S1, V60, pA59
[7]
Thermal comfort in urban transitional spaces [J].
Chun, C ;
Tamura, A .
BUILDING AND ENVIRONMENT, 2005, 40 (05) :633-639
[8]
Thermal comfort in transitional spaces - basic concepts: literature review and trial measurement [J].
Chun, C ;
Kwok, A ;
Tamura, A .
BUILDING AND ENVIRONMENT, 2004, 39 (10) :1187-1192
[9]
Thermal environment and human responses in underground shopping malls vs department stores in Japan [J].
Chun, CY ;
Tamura, A .
BUILDING AND ENVIRONMENT, 1998, 33 (2-3) :151-158
[10]
De Dear R.J., 1993, Indoor Air, V3, P181, DOI [10.1111/j.1600-0668.1993.t01-1-00004.x, DOI 10.1111/J.1600-0668.1993.T01-1-00004.X]