Changes in allograft bone irradiated at different temperatures

被引:72
作者
Hamer, AJ [1 ]
Stockley, I [1 ]
Elson, RA [1 ]
机构
[1] No Gen Hosp, Dept Orthopaed Surg, NHS Trust, Sheffield S5 7AU, S Yorkshire, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1999年 / 81B卷 / 02期
关键词
D O I
10.1302/0301-620X.81B2.9083
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Secondary sterilisation of allograft bone by gamma irradiation is common, but the conditions under which it is performed vary between tissue banks. Some do so at room temperature, others while the bone is frozen, Bone is made brittle by irradiation because of the destruction of collagen alpha chains, probably mediated by free radicals generated from water molecules. Freezing reduces the mobility of water molecules and may therefore decrease the production of free radicals, We found that bone irradiated at -78 degrees C was less brittle and had less collagen damage than when irradiated at room temperature. These findings may have implications for bone-banking.
引用
收藏
页码:342 / 344
页数:3
相关论文
共 9 条
[1]   COMPRESSIVE MECHANICAL-PROPERTIES OF HUMAN CANCELLOUS BONE AFTER GAMMA-IRRADIATION [J].
ANDERSON, MJ ;
KEYAK, JH ;
SKINNER, HB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (05) :747-752
[2]  
CAMPBELL DG, 1994, INT ORTHOP, V18, P172
[3]  
DZIEDZICGOCLAWSKA A, 1991, CLIN ORTHOP RELAT R, P30
[4]   EFFECTS OF GAMMA-IRRADIATION ON THE HUMAN-IMMUNODEFICIENCY-VIRUS - A STUDY IN FROZEN HUMAN BONE-PATELLAR LIGAMENT-BONE GRAFTS OBTAINED FROM INFECTED CADAVERA [J].
FIDELER, BM ;
VANGSNESS, CT ;
MOORE, T ;
LI, ZL ;
RASHEED, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (07) :1032-1035
[5]   Biomechanical properties of cortical allograft bone using a new method of bone strength measurement - A comparison of fresh, fresh-frozen and irradiated bone [J].
Hamer, AJ ;
Strachan, JR ;
Black, MM ;
Ibbotson, CJ ;
Stockley, I ;
Elson, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03) :363-368
[6]   A NEW METHOD OF COMPARATIVE BONE STRENGTH MEASUREMENT [J].
HAMER, AJ ;
STRACHAN, JR ;
BLACK, MM ;
IBBOTSON, C ;
ELSON, RA .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1995, 19 (01) :1-5
[7]  
HAMER AJ, 1995, J BONE MIN REA, V10, P339
[8]   INACTIVATION OF HUMAN-IMMUNODEFICIENCY-VIRUS BY GAMMA-RADIATION AND ITS EFFECT ON PLASMA AND COAGULATION-FACTORS [J].
HIEMSTRA, H ;
TERSMETTE, M ;
VOS, AHV ;
OVER, J ;
VANBERKEL, MP ;
DEBREE, H .
TRANSFUSION, 1991, 31 (01) :32-39
[9]  
Stachowicz W, 1970, STERILIZATION PRESER, P15