Simultaneous determination of Pt and I by ICP-MS for studies of the mechanism of reaction of diiodoplatinum anticancer complexes

被引:12
作者
Patriarca, M [1 ]
Kratochrvil, NA [1 ]
Sadler, PJ [1 ]
机构
[1] Univ Edinburgh, Dept Chem, Edinburgh EH9 3JJ, Midlothian, Scotland
关键词
D O I
10.1039/a807981a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of Pt by ICP-MS in environmental and biological samples is well documented and generally performed after dissolution in dilute HNO3. On the other hand, I is poorly ionised in the plasma and, at low pH? memory effects and instability arise from the formation of potentially volatile species, such as I-2 and HI, depending on the oxidation state of I. In order to investigate the role of iodo ligands in the design of Pt anticancer complexes, we have optimised conditions for the simultaneous determination of Pt and I. Standards and samples were diluted in 10 mM KOH and improved ion extraction into the quadrupole was achieved by means of an additional pump (S-Option(TM)), leading to about a 2-fold increased sensitivity. The limits of detection in water were 10 and 0.6 ng l(-1) for I and PI, respectively, but. increased to 23 ng l(-1) for I and 2.2 ng l(-1) for Pt in KOH (10 mM). The analysis of certified reference materials yielded the following results: 0.84 +/- 0.05 mu g g(-1) I (certified value: 0.81 +/- 0.05 mu g g(-1)) in BCR CRM 063R 'Skimmed Milk Powder', and 0.121 +/- 0.006 mu g ml(-1) Pt (indicative value: 0.12 mu g ml(-1)) in NIST SRM 2670 'Toxic Metals in Urine'. Pt:I ratios ranging from 0.240 to 1.035 were measured with an accuracy of 101.3 +/- 2.4%. The determination of the Pt:I ratio in the low M-r fraction of reaction mixtures of diiodo Pt complexes and human albumin provided evidence for the release of iodide and for different kinetics for the reactions of diiodo Pt(rv) and Pt(rr) complexes.
引用
收藏
页码:633 / 637
页数:5
相关论文
共 24 条
[1]   SIGNAL ENHANCEMENT OF ELEMENTS DUE TO THE PRESENCE OF CARBON-CONTAINING COMPOUNDS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
JAUNAULT, L ;
MAURAS, Y ;
MERMET, JM ;
DELAPORTE, T .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1497-1498
[2]   Analytical methods for the determination of platinum in biological and environmental materials [J].
Balcerzak, M .
ANALYST, 1997, 122 (05) :R67-R74
[3]   RAPID AND SENSITIVE DETERMINATION OF IODINE IN FRESH MILK AND MILK POWDER BY INDUCTIVELY COUPLED PLASMA - MASS-SPECTROMETRY (ICP-MS) [J].
BAUMANN, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (07) :809-812
[4]  
BERGEROW J, 1997, J ANAL ATOM SPECTROM, V12, P1095
[5]  
Cairns WRL, 1997, SPECTROSCOPY, V12, P16
[6]   DETERMINATION OF TOTAL ARSENIC CONCENTRATIONS IN BIOLOGICAL MATRICES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
CAMPBELL, MJ ;
DEMESMAY, C ;
OLLE, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (12) :1379-1384
[7]  
CARTER DC, 1994, ADV PROTEIN CHEM, V45, P153
[8]   Determination of gold and platinum in the presence of blood plasma proteins using inductively coupled plasma mass spectrometry with direct injection nebulization [J].
Christodoulou, J ;
Kashani, M ;
Keohane, BM ;
Sadler, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (11) :1031-1035
[9]   Determination of total iodine in nutritional and biological samples by ICP-MS following their combustion within an oxygen stream [J].
Gélinas, Y ;
Krushevska, A ;
Barnes, RM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :1021-1025
[10]  
Haldimann M, 1998, CLIN CHEM, V44, P817