Computer-Aided Volumetric Comparison of Reconstructed Orbits for Blow-Out Fractures With Nonpreformed Versus 3-Dimensionally Preformed Titanium Mesh Plates: A Preliminary Study

被引:28
作者
Scolozzi, Paolo [1 ]
Momjian, Armen [1 ]
Heuberger, Joris [2 ]
机构
[1] Hop Univ Geneve, Serv Oral & Maxillofacial Surg, Dept Surg, CH-1211 Geneva, Switzerland
[2] Hop Univ Geneve, Dept Med Images & Informat Sci, CH-1211 Geneva, Switzerland
关键词
orbital fractures; volume measurement; titanium mesh plates; computer tomography; POSTTRAUMATIC ENOPHTHALMOS; TOMOGRAPHY; FLOOR; IMPLANT; WALL; PREDICTION; FAT;
D O I
10.1097/RCT.0b013e3181ac1975
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Objectives: To compare and evaluate, using computer-aided volumetric measurements, the accuracy and reliability of nonpreformed mesh plates (NPMPs) versus 3-dimensionally preformed titanium mesh plates (PMPs) in posttraumatic orbital volume restoration. Patients and Methods: Facial coronal computed tomographic scan slices from 20 patients (10 in the NPMP and 10 in the PMP group) were used to measure bony orbital volume using OsiriX Medical Image software (version 3.3.2, www.osirix-viewer.com). The procedure was performed on both orbits; thereafter, the volume of the contralateral health orbit was used as a control for comparison in the 2 groups of patients. The difference in orbital volume between the 2 groups and between the reconstructed versus uninjured side in both groups have been statistically correlated. Results: The mean orbital volume between the reconstructed (19.215 mL in NPMP and 21.791 mL in PMP) and the contralateral uninjured side (18.955 mL in NPMP and 21.710 mL in PMP) was not statistically significant (P > 0.05). The mean orbital volumes of the reconstructed orbits were 19.215 mL in the NPMP and 21.791 mL in the PMP group, with no statistically significant difference (P > 0.05). The volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with an accuracy of a maximum of 1.85 mL in the NPMP group and 2.5 mL in the PMP group. Conclusions: The Current study demonstrated that there were no significant differences in the orbital Volume restoration using either technique. In fact, both techniques allow for close reproduction of natural orbital volume and shape, and its use in posttraumatic orbital wall reconstruction was successful.
引用
收藏
页码:98 / 104
页数:7
相关论文
共 34 条
[1]
ORBITAL VOLUME MEASUREMENTS IN ENOPHTHALMOS USING 3-DIMENSIONAL CT IMAGING [J].
BITE, U ;
JACKSON, IT ;
FORBES, GS ;
GEHRING, DG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1985, 75 (04) :502-507
[2]
ORBITAL VOLUME MEASUREMENT IN THE MANAGEMENT OF PURE BLOWOUT FRACTURES OF THE ORBITAL FLOOR [J].
CHARTERIS, DG ;
CHAN, CH ;
WHITEHOUSE, RW ;
NOBLE, JL .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (02) :100-102
[3]
New frontiers in calvarial reconstruction: Integrating computer-assisted design and tissue engineering in cranioplasty [J].
Chim, H ;
Schantz, JT .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2005, 116 (06) :1726-1741
[4]
Dolynchuk K N, 1996, J Craniomaxillofac Trauma, V2, P56
[5]
Assessment of internal orbital reconstructions for pure blowout fractures: Cranial bone grafts versus titanium mesh [J].
Ellis, E ;
Tan, YH .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (04) :442-453
[6]
Cranial reconstruction with computer generated hard-tissue replacement patient matched implants: Indications, surgical technique, and long-term follow-up [J].
Eppley, BL ;
Kilgo, M ;
Coleman, JJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 109 (03) :864-871
[7]
Computer-assisted orbital volume measurement in the surgical correction of late enophthalmos caused by blowout fractures [J].
Fan, XQ ;
Li, J ;
Zhu, J ;
Li, HS ;
Zhang, DS .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 19 (03) :207-211
[8]
VOLUME MEASUREMENTS OF NORMAL ORBITAL STRUCTURES BY COMPUTED TOMOGRAPHIC ANALYSIS [J].
FORBES, G ;
GEHRING, DG ;
GORMAN, CA ;
BRENNAN, MD ;
JACKSON, IT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (01) :149-154
[9]
Safety of titanium mesh for orbital reconstruction [J].
Gear, AJL ;
Lokeh, A ;
Aldridge, JH ;
Migliori, MR ;
Benjamin, CI ;
Schubert, W .
ANNALS OF PLASTIC SURGERY, 2002, 48 (01) :1-7
[10]
Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity [J].
Gellrich, NC ;
Schramm, A ;
Hammer, B ;
Rojas, S ;
Cufi, D ;
Lagrèze, W ;
Schmelzeisen, R .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 110 (06) :1417-1429