Two-dimensional separation system of coupling capillary liquid chromatography to capillary electrophoresis for analysis of Escherichia coli metabolites

被引:22
作者
Jia, L
Tanaka, N
Terabe, S
机构
[1] Univ Hyogo, Grad Sch Mat Sci, Kamigori, Hyogo, Japan
[2] Kyoto Inst Technol, Dept Polymer Sci & Engn, Sakyo Ku, Kyoto 606, Japan
关键词
capillary electrophoresis; capillary liquid chromatography; Escherichia coli; metabolome analysis; two-dimensional separation system;
D O I
10.1002/elps.200500308
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A two-dimensional (2-D) separation system of coupling chromatography to electrophoresis was developed for profiling Escherichia coli metabolites. Capillary liquid chromatography (LC) with a monolithic silica-octaclecyl silica column (500 x 0.2 mm ID) was used as the first dimension, from which the effluent fractions were further analyzed by capillary electrophoresis (CE) acting as the second dimension. Field-enhanced stacking was selectively employed as a concentration strategy to interface the two dimensions, which proved to be beneficial for the detection of metabolites. An artificial sample containing 118 standards, some of which lack chromophores or have weak UV absorbance, was used to optimize the 2-D separation system. Under the optimum conditions, 63 components in the artificial sample having absorbance at 254 nm could be well resolved and detected. The utility of the system was demonstrated by comprehensive analysis of E coli metabolites. Comparing with the previous 2-D separation system we published in AnaL Chem. 2004, 76, 1419-1428, using a longer monolithic column in the first dimension improved the separation efficiency and offered the possibility of increasing the injection volume without compromising the separation efficiency. In the second dimension, field-enhanced stacking was used to improve the concentration sensitivity of the metabolites, and more metabolites in E coli cell extract were detected and identified using the developed 2-D separation system. In addition, preliminary investigation for future CE-mass spectrometry coupling was also made in the study by using volatile buffers in the capillary LC and CE techniques.
引用
收藏
页码:3468 / 3478
页数:11
相关论文
共 33 条
[1]   Selective focusing of catecholamines and weakly acidic compounds by capillary electrophoresis using a dynamic pH junction [J].
Britz-McKibbin, P ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1242-1252
[2]   Velocity-difference induced focusing of nucleotides in capillary electrophoresis with a dynamic pH junction [J].
Britz-McKibbin, P ;
Bebault, GM ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1729-1735
[3]   ON-COLUMN SAMPLE CONCENTRATION USING FIELD AMPLIFICATION IN CZE [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :A489-A496
[4]   Silica xerogel as a continuous column support for high-performance liquid chromatography [J].
Fields, SM .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2709-2712
[5]   CONCEPTS AND COMPARISONS IN MULTIDIMENSIONAL SEPARATION [J].
GIDDINGS, JC .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :319-323
[6]  
Issaq HJ, 2001, ELECTROPHORESIS, V22, P3629, DOI 10.1002/1522-2683(200109)22:17<3629::AID-ELPS3629>3.0.CO
[7]  
2-O
[8]   Two-dimensional separation method for analysis of Bacillus subtilis metabolites via hyphenation of micro-liquid chromatography and capillary electrophoresis [J].
Jia, L ;
Liu, BF ;
Terabe, S ;
Nishioka, T .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1419-1428
[9]   Advances in capillary electrochromatography and micro-high performance liquid chromatography monolithic columns for separation science [J].
Legido-Quigley, C ;
Marlin, ND ;
Melin, V ;
Manz, A ;
Smith, NW .
ELECTROPHORESIS, 2003, 24 (06) :917-944
[10]   FIELD-AMPLIFIED SAMPLE STACKING IN MICELLAR ELECTROKINETIC CHROMATOGRAPHY FOR ON-COLUMN SAMPLE CONCENTRATION OF NEUTRAL MOLECULES [J].
LIU, ZY ;
SAM, P ;
SIRIMANNE, SR ;
MCCLURE, PC ;
GRAINGER, J ;
PATTERSON, DG .
JOURNAL OF CHROMATOGRAPHY A, 1994, 673 (01) :125-132