Preservation of humidity and heat of respiratory gases in spontaneously breathing, tracheostomized patients

被引:19
作者
Thomachot, L
Viviand, X
Arnaud, S
Vialet, R
Albanese, J
Martin, C
机构
[1] Marseille Univ Hosp, Hop Nord, Dept Anesthesia & Intens Care, Marseilles Sch Med, F-13914 Marseille 15, France
[2] Marseille Univ Hosp, Hop Nord, Ctr Trauma, Marseilles Sch Med, F-13914 Marseille 15, France
关键词
heat and moisture exchanger; heated humidifier system; humidification of ventilatory gas;
D O I
10.1111/j.1399-6576.1998.tb05331.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Ventilation with endotracheal intubation bypasses the upper airway and the normal heat and moisture exchanging process of inspired gases. A continuous loss of moisture and heat occurs and predisposes patients to serious airway damage. We therefore prospectively studied one heated humidifier system, one cold humidifier system and one heat and moisture exchanger in spontaneously breathing, tracheostomized intensive care unit patients to determine the ability to preserve patients' heat and water. Methods: Following a randomized order, 10 patients were spontaneously ventilated for 24-h periods with the Nam 35(R) humidifier (Europe Medical, France, a cold water humidifier), the heat and moisture exchanger Trach-Vent(R) (Gibeck, Sweden), and the Aerodyne(R) humidifer (Kendall, USA). in each patient, during the inspiration phase, the following measurements were performed: mean values of temperature and relative humidity of inspired gases. The absolute humidity was calculated. Values were obtained in each patients after 40 min and 24 h. Results: The Trach-Vent(R) filter and the Aerodyne(R) humidifier had better humidification and thermic capacities than the Nam 35(R) humidifier (P<0.001). With the Nam 35(R) humidifier, no patient had temperature of inspired gas >29 degrees C Concerning absolute humidity of inspired gases, the Nam 35(R) humidifier achieved a lower performance than the other two tested systems (P<0.001). Conclusion: In spontaneously breathing, tracheostomized intensive care unit patients, the Trach-Vent(R) heat and moisture exchanger and the Aerodyne(R) heated system achieved satisfactorily preservation of heat and humidity of inspired gases.
引用
收藏
页码:841 / 844
页数:4
相关论文
共 23 条
[1]   HUMIDIFICATION IN ANESTHESIA - REVIEW OF PRESENT SITUATION [J].
BOYS, JE ;
HOWELLS, TH .
BRITISH JOURNAL OF ANAESTHESIA, 1972, 44 (08) :879-+
[2]   HUMIDITY AND THE ANESTHETIZED PATIENT [J].
CHALON, J ;
PATEL, C ;
ALI, M ;
RAMANATHAN, S ;
CAPAN, L ;
TANG, CK ;
TURNDORF, H .
ANESTHESIOLOGY, 1979, 50 (03) :195-198
[3]  
CIGADA M, 1990, INTENSIVE CARE WORLD, V7, P98
[4]  
CRAVEN DE, 1984, AM REV RESPIR DIS, V129, P625
[5]   EVOLUTION OF HEAT AND MOISTURE IN RESPIRATORY TRACT DURING ANESTHESIA WITH A NON-REBREATHING SYSTEM [J].
DERY, R .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1973, 20 (03) :296-309
[6]  
DERY R., 1967, CAN ANAESTH SOC J, V14, P287, DOI 10.1007/BF03003698
[7]   LABORATORY EVALUATION OF HEAT AND MOISTURE EXCHANGERS - ASSESSMENT OF THE DRAFT INTERNATIONAL STANDARD (ISO/DIS 9360) IN PRACTICE [J].
ECKERBOM, B ;
LINDHOLM, CE .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (04) :291-295
[8]   PERFORMANCE EVALUATION OF 6 HEAT AND MOISTURE EXCHANGERS ACCORDING TO THE DRAFT INTERNATIONAL STANDARD (ISO DIS-9360) [J].
ECKERBOM, B ;
LINDHOLM, CE .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (05) :404-409
[9]  
INGELSTEDT S, 1956, ACTA OTO-LARYNGOL, P131
[10]  
LATHAM MJ, 1981, 2044 BM F PALL EUR L