Activity patterns of patients with diabetic foot ulceration - Patients with active ulceration may not adhere to a standard pressure off-loading regimen

被引:200
作者
Armstrong, DG
Lavery, LA
Kimbriel, HR
Nixon, BP
Boulton, AJM
机构
[1] So Arizona Vet Affairs Med Ctr, Dept Surg, Tucson, AZ 85723 USA
[2] Manchester Royal Infirm, Dept Med, Manchester M13 9WL, Lancs, England
[3] Scott & White Mem Hosp & Clin, Temple, TX 76508 USA
[4] Univ Miami, Dept Med, Miami, FL USA
关键词
D O I
10.2337/diacare.26.9.2595
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To evaluate the activity of patients with diabetic foot ulcerations and their adherence to their pressure off-loading device. RESEARCH DESIGN AND METHODS - We enrolled 20 Subjects treated for neuropathic diabetic foot wounds corresponding to University of Texas grade I Stage A. All were, off-loaded using a removable Cast walker (RCW). We recorded the total activity (measured in activity steps per day) taken on a waist-worn computerized accelerometer. We subsequently correlated this to activity recorded on an RCW-mounted accelerometer, which was not readily accessible to the patient RESULTS - There were a mean 1,219.1 +/- 821.2 activity Units (steps) taken per patient per day. Patients logged significantly more daily activity units with the protective RCW off than with it on (873.7 +/- 828.0 vs. 345.3 +/- 219.1, P = 0.01). This amounts to only 28% of total daily activity recorded while patients were wearing their RCW. Although a total of 130% of the patients in the study recorded more daily activity units white wearing the device, this subset most adherent to their off-loading regimen still only wore the device for a total of 60% of their total daily activity. CONCLUSIONS - Subjects with diabetic foot ulcerations appear to wear their off-loading devices for only a minority of steps taken each day. This may partially explain the poor results reported from many trials of agents designed to help speed the healing of these wounds. Control of this important aspect of care with less easily removable devices may increase the prevalence of healing.
引用
收藏
页码:2595 / 2597
页数:3
相关论文
共 17 条
[1]  
Alvarez Oscar M, 2003, J Foot Ankle Surg, V42, P30
[2]  
American Diabetes Association, 1999, DIABETES CARE, V22, P1354, DOI DOI 10.2337/DIACARE.22.8.1354
[3]   Validation of a diabetic wound classification system - The contribution of depth, infection, and ischemia to risk of amputation [J].
Armstrong, DG ;
Lavery, LA ;
Harkless, LB .
DIABETES CARE, 1998, 21 (05) :855-859
[4]   Off-loading the diabetic foot wound - A randomized clinical trial [J].
Armstrong, DG ;
van Schie, CHM ;
Nguyen, HC ;
Boulton, AJM ;
Lavery, LA ;
Harkless, LB .
DIABETES CARE, 2001, 24 (06) :1019-1022
[5]   A comparison study of plantar foot pressure in a standardized shoe, total contact cast, and prefabricated pneumatic walking brace [J].
Baumhauer, JF ;
Wervey, R ;
McWilliams, J ;
Harris, GF ;
Shereff, MJ .
FOOT & ANKLE INTERNATIONAL, 1997, 18 (01) :26-33
[6]   Recombinant human platelet-derived growth factor-BB (becaplermin) for healing chronic lower extremity diabetic ulcers: an open-label clinical evaluation of efficacy [J].
Embil, JM ;
Papp, K ;
Sibbald, G ;
Tousignant, J ;
Smiell, JM ;
Wong, B ;
Lau, CY .
WOUND REPAIR AND REGENERATION, 2000, 8 (03) :162-168
[7]  
Frykberg R G, 2000, J Foot Ankle Surg, V39, pS1
[8]   Use of dermagraft, a cultured human dermis, to treat diabetic root ulcers [J].
Gentzkow, GD ;
Iwasaki, SD ;
Hershon, KS ;
Mengel, M ;
Prendergast, JJ ;
Ricotta, JJ ;
Steed, DP ;
Lipkin, S .
DIABETES CARE, 1996, 19 (04) :350-354
[9]   Predictive value of foot pressure assessment as part of a population-based diabetes disease management program [J].
Lavery, LA ;
Armstrong, DG ;
Wunderlich, RP ;
Tredwell, J ;
Boulton, AJM .
DIABETES CARE, 2003, 26 (04) :1069-1073
[10]   Reducing dynamic foot pressures in high-risk diabetic subjects with foot ulcerations - A comparison of treatments [J].
Lavery, LA ;
Vela, SA ;
Lavery, DC ;
Quebedeaux, TL .
DIABETES CARE, 1996, 19 (08) :818-821